1-18
API Confidential
No Copy/Reproduction Allowed
7277e Monitor Service Guide
1.5.5 Packaging
1.5.5.1 Carton Dimension
TBD
1.5.5.2 Shipping Weight
20.5Kg
1.6 Maintainability Specifications
1.6.1 General & Requirements
1.6.1.1 Installation
From outside of unit with standard tools and documentation provided to user.
1.6.1.2 Periodic Maintenance
No periodic maintenance is required.
1.6.1.3 Repair & Calibration
Require equipment and spare modules or components as specified as followings:
(1) MAIN ASSY P/N
55.70601.001
(2) CRT ASSY P/N
55.70602.001
1.6.2 Mean Time to Repair
1.6.2.1 Module Level
Less than 10 minutes
1.6.2.2 Component Level
Less than 15 minutes
1.6.3 Accessibility
1.6.3.1 General
All panels, covers, and major assemblies are removable without disruption of permanent
mounting or fasteners.
1.6.3.2 Outside Cabinet, Access to the Following Elements
-Operating Controls: see section 4-3
-Power Connectors: see section 3-2
1.6.3.3 Cover Removal, Access
All sub assemblies and internally adjustable components may be accessed by removing the
bucket and the bezel together.
1.6.4 Equipment & Tools Required
1.6.4.1 Standard Test Equipment
(1) Voltmeter
(2) Dual trace oscilloscope
(3) High voltage probe
(4) Hand tools as required
(5) Color analyzer, Minolta TV2130 or equivalent.
(6) Pattern Generator CHROME-2000 (or equivalent).
6.4.2 Documentation
A service manual will be available which covers all service requirements. A users manual written
in German, Italian, and English will be available to ship with the product.