Horizon Series Owner’s Manual 

 

6

 

i. Control board may be defective

ii. Bypass valve may be defective

7. After routine maintenance has been completed, return humidistat to desired setting.

If any problems occur during routine maintenance, contact your contractor or the factory.

 

Specifications: 

MODEL 

See Data Label 

HEIGHT 

16” 

WIDTH 

13.8” 

LENGTH 

23” 

WEIGHT 

62.00 LBS 

AIRFLOW 

350 CFM 

MOISTURE REMOVAL 
AT 80F/60% RH 

See Data Label 

POWER SUPPLY 

115 VOLT/60 HERTZ SINGLE 

PHASE 

FINISH 

POWDER-COATED EPOXY 

OPERATING RANGE 

33 F TO 90 F 

REFRIGERANT 

See Data Label 

CONDENSATE DRAIN SIZE 

¾” MPT 

AMPS (FULL LOAD) 
AT 80F/60% 

See Data Label 

POWER CORD 

20’ GROUDED PLUG 

FILTER SIZE 

11x11” (Washable/Reusable) 

Содержание Horizon Series

Страница 1: ...izon Series Owner s Manual 1 H Ho or ri iz zo on n C Cr ra aw wl ls sp pa ac ce e S Se er ri ie es s I In ns st ta al ll la at ti io on n a an nd d O Op pe er ra at ti io on ns s M Ma an nu ua al l R...

Страница 2: ...oughout unit the unit should be opened and allowed to dry thoroughly before reconnected to electric and restarting For proper operation neither the inlet nor discharge should be positioned against a w...

Страница 3: ...ous injury from electric shock 1 Disconnect electrical power before servicing 2 Plug unit only into grounded electrical outlet 3 Do not use extension cord 4 Do not use plug adapter Power Supply 115V 6...

Страница 4: ...NG If after unit is positioned it is moved in such a manner that the compressor didn t remain in a vertical orientation wait a minimum of 2 hours before turning the unit on Drain Line o Standard Unit...

Страница 5: ...ximately 3 minutes Warning Never apply an external source of heat to melt ice off coil Maintenance Annual Inspection of Coils and drain line is required 1 Unplug Unit 2 Filter may be cleaned by a Vacu...

Страница 6: ...ems occur during routine maintenance contact your contractor or the factory Specifications MODEL See Data Label HEIGHT 16 WIDTH 13 8 LENGTH 23 WEIGHT 62 00 LBS AIRFLOW 350 CFM MOISTURE REMOVAL AT 80F...

Страница 7: ...Ho or ri iz zo on n S Se er ri ie es s P Pa ar rt ts s L Li is st t Item Description 1 Compressor 2 Humidistat 3 Fan Motor 4 Fan Blade 5 Thermostat 6 Capacitor 7 Relay 8 Solenoid Coil 9 Solenoid Valve...

Страница 8: ...s not include any cost of labor including but not limited to labor to remove and or reinstall any defective part refrigerant or piping Customer may elect to have unit fixed locally in which case requi...

Отзывы: