Owner’s Manual
Models:
FXD-ACD36
FXD-ACD60
Please read this owner’s manual carefully
before operating the unit and keep it for future reference.
Central heat pump unit
Страница 1: ...Owner s Manual Models FXD ACD36 FXD ACD60 Please read this owner s manual carefully before operating the unit and keep it for future reference Central heat pump unit...
Страница 2: ...duct is not to be used for long cut off the power supply please energize and preheat the unit in advance before reusing it 3 Please properly select the model according to actual using environment othe...
Страница 3: ...to ACD Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons 1 Damage the product due to improper use or misuse of the p...
Страница 4: ...or Code 27 4 3 Unit Maintenance 28 4 4 Notice on Maintenance 29 4 5 After Sales Services 34 This marking indicates that this product should not be disposed with other household wastes throughout the E...
Страница 5: ...dual instructions packaged with the kits or accessories when installing Follow all safety codes Wear safety glasses protective clothing and work gloves Use quenching cloth for brazing operations Have...
Страница 6: ...tion materials including nails metal or wooden parts and plastic packing material must be treated in a safe way 1 Please install according to this instruction manual Installation must be performed in...
Страница 7: ...Do not operate the air conditioner with wet hands Do not wash or sprinkle water on the air conditioner otherwise malfunction or electric shock will occur 15 Do not dry the filter with naked flame or a...
Страница 8: ...tect the outdoor unit from small animals because they may damage the electric components and cause malfunction of the air conditioner 1 If thermostat is to be used it should be connected first before...
Страница 9: ...e Q ty Usage 1 Throw over pipe 1 Connect the unit with the liquid pipe 2 Throw over pipe 1 Connect the unit with the gas pipe 3 Installation 3 1 Installation Preparation 3 1 1 Selection of Installatio...
Страница 10: ...at may obstruct the air inlet and outlet 4 The installation location should be able to withstand the weight and vibration of outdoor unit and allow the installation to be carried out safely 5 Avoid in...
Страница 11: ...0 FXD ACD60 Unit inch mm Dimensions Model A B C D E G FXD ACD60 42 3 4 1085 16 7 8 427 53 3 4 1365 24 1 2 620 15 1 2 395 14 1 2 370 3 1 3 Diagram of Unit Installation Space and Location Diagram of ins...
Страница 12: ...nstalled A E Hb Hd H mm a b c d e B 100 A B C 300 100 100 B E 100 1000 A B C E 300 150 150 1000 D 1000 D E 1000 1000 B D Hb Hd Hd H 100 1000 Hb Hd Hd H 100 1000 B D E Hb Hd Hb 1 2H 250 2000 1000 1 2H...
Страница 13: ...side by side Unit mm A E Hb Hd H mm a b c d e A B C 300 300 1000 A B C E 300 300 1000 1000 D 2000 D E 2000 1000 B D Hb Hd Hd H 300 2000 Hb Hd Hd 1 2H 250 2000 1 2H Hd H 300 2500 B D E Hb Hd Hb 1 2H 3...
Страница 14: ...h Series for R410A Unitary Split Air Conditioner 10 3 When outdoor units are installed in rows Unit mm Hb H mm Hb 1 2H b 250 1 2H Hb H b 300 Hb H Prohibited 4 When outdoor units are installed one abov...
Страница 15: ...base 3 When the outdoor unit is in heating or defrosting it needs to drain water When installing the drain pipe plug the accompanied drainage connector to the drainage hole on the chassis of the outdo...
Страница 16: ...anical damage during installation maintenance and transportation Item Model Size of fitting pipe inch Maximum pipe length feet m Biggest drop between indoor and outdoor units feet m Liquid pipe Gas pi...
Страница 17: ...ng 1 The pipes are shaped by your hands Be careful not to collapse them 2 Do not bend the pipes in an angle more than 90 3 If the pipe is repeatedly bent or extended it will become hard and difficult...
Страница 18: ...ning torque by referring to the following table If the screw nut is over twisted it may be damaged and cause leakage Check whether gas leakage occurs to the connection pipe and then apply thermal insu...
Страница 19: ...3 1 Vacuum Pumping Make sure the outlet of vacuum pump is away from fire source and is well ventilated Before vacuum pumping make sure the unit cut off valves are closed When vacuum pumping both the l...
Страница 20: ...ressure gauge at the low pressure side can not be larger than 0 005MPa 7 Slightly open the liquid valve and let some refrigerant go to the connection pipe to balance the pressure inside and outside of...
Страница 21: ...inage Pipe 1 If the outdoor unit is underneath the indoor unit arrange the pipeline according to the following diagram 1 Drain hose should be placed on the ground and its end should not be immersed in...
Страница 22: ...circuit must be equipped with a circuit breaker and air switch both with sufficient capacity The unit s operating power must be within the nominal range stated in the instruction manual Use a speciali...
Страница 23: ...rules and regulations This outdoor unit has a heating four way valve 3 3 2 Electrical Parameters Model Power supply Fuse capacity A Maximum over current protection A Minimum circuit ampacity A FXD AC...
Страница 24: ...up the terminal screw as shown below Unit mm inch 3 How to connect the thermostat wires and power cords Lead the thermostat wires and power cords through the insulation tube as shown in the following...
Страница 25: ...to connect the D terminals High and low voltage wires should be led through different rubber rings of the front plate Do not bundle up the thermostat wires or lay them side by side otherwise errors wi...
Страница 26: ...the phase sequence of the power supply matches with the corresponding terminals otherwise the compressor will get reversed and operate abnormally Remove the big handle front panel of the outdoor unit...
Страница 27: ...produce noise Did you do water leakage test Cooling capacity may become unsatisfactory Is the unit well insulated from heat Condensate water drops may occur Does water drainage go well Condensate wat...
Страница 28: ...y 5 After checking re install the front side plate Operation after connecting the power 1 If all the above works are finished power on the unit 2 If the outside temperature is more than 30 C heating m...
Страница 29: ...e wiring diagram Fuse or circuit breaker is broken Replace the fuse or switch on the circuit breaker Power failure Restart after power is resumed Power plug is loose Re insert the power plug Bad cooli...
Страница 30: ...About 30s later the purr of the unit becomes low About 20s after the unit first enables the heating mode or there is refrigerant brushing sound when defrosting under heating It s the sound of 4 way v...
Страница 31: ...normal situations it may get damaged and cause electric shock or fire hazard Do not repair the air conditioner by yourself Improper maintenance will cause electric shock or fire hazard Please contact...
Страница 32: ...ot let any inflammable objects near the unit Do not use organic solvent to clean the air conditioner If you need to replace a component please ask a professional to repair with a component supplied by...
Страница 33: ...le 3 Check if the air filter screen is properly installed 4 If starting up again after long term shut down preset the power switch of air conditioner to ON status before 8h of operation to preheat the...
Страница 34: ...Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If...
Страница 35: ...ed Components 4 4 2 1 Electrical Safety From the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during se...
Страница 36: ...r continual vibration from sources such as compressors or fans 4 4 5 Charging Procedures In addition to conventional charging procedures the following requirements shall be followed 1 Ensure that cont...
Страница 37: ...he appropriate standards 4 Pump down refrigerant system if possible 5 If a vacuum is not possible make a manifold so that refrigerant can be removed from various parts of the system 6 Make sure that c...
Страница 38: ...te with leak free disconnect couplings and in good condition Before using the recovery machine check that it is in satisfactory working order has been properly maintained Consult manufacturer if in do...