REV - B

4Sight Ophthalmic 

Diagnostic Unit

Quick Reference Guide

Содержание 4Sight

Страница 1: ...REV B 4Sight Ophthalmic Diagnostic Unit Quick Reference Guide ...

Страница 2: ...2020 610 889 0200 International 31 0 485 350300 Europe or visit www accutome com INDEX A Scan 3 How To Measure A New Patient 3 B Scan 4 How To Measure A New Patient 4 UBM 6 How To Measure A New Patient 6 Pachymeter 8 How To Measure A New Patient 8 ...

Страница 3: ...ep Seven Pin back patient s lids and place shell directly over the cornea Fill shell with BSS past probe tip until waveforms are displayed on screen 6 Step Six When in auto mode begin with foot pedal pressed 8 Step Eight Release foot pedal when spikes are acceptable and machine will auto capture if automatic capture mode is selected 9 Step Nine Ensure all wave forms are within 0 1mm immersion and ...

Страница 4: ...gnostic Support at info accutome com or 610 889 0200 12 Step Twelve Save the patient info buy clicking the Save icon at the bottom of the screen B SCAN How To Measure A New Patient 1 Step One Begin a new patient by selecting New Patient 3 Step Three Select the appropriate Scan Group and Protocol 2 Step Two Type the patient data into the appropriate fields 4 Step Four Launch B Scan Mode by clicking...

Страница 5: ...ewing desired report back out of preview and select Save to save current report NOTE You can also select Review to bring up a list of all other reports saved for selected patient Print will send the current report to printer Export to DICOM will send the selected report to the previously setup DICOM location see Manual 10 Step Ten Under Report your snapshots will be viewable Hold the Ctrl or Shift...

Страница 6: ...s 4 Step Four Launch UBM Mode by clicking the UBM icon 6 Step Six Press the button on the probe or use the foot pedal to activate probe and start video loop 5 Step Five Setup probe for appropriate measurement technique Clear Scan or Scleral Shells 7 Step Seven Ensure image pathology is centered on the screen for several moments before stopping the video loop by pressing the button or foot pedal 8 ...

Страница 7: ... report NOTE You can also select Review to bring up a list of all other reports saved for selected patient Print will send the current report to printer Export to DICOM will send the selected report to the previously setup DICOM location see Manual 11 Step Eleven Under Report your snapshots will be viewable Hold the Ctrl or Shift key down and select the snapshots that are desired to be placed into...

Страница 8: ...ch B Scan Mode by clicking the Pachymeter icon 4 Step Four On the measurement screen choose the eye OD OS and then choose the scan location on the cornea 6 Step Six Place probe on the eye in the location selected on the screen The flat portion of the probe tip should be completely in contact perpendicular with the patient s cornea not at an angle Measurements will not be obtained unless the probe ...

Страница 9: ...right of the screen 8 Step Eight Another location for the eye can be selected and measured or switch eyes and repeat measurement steps 9 Step Nine Save the patient info buy clicking the Save icon at the bottom of the screen 10 Step Ten After Save select the Report icon Selecting this icon will generate a Pachymetry Report For assistance with navigating the device or any other questions please feel...

Страница 10: ... for most brands of Diamond Knives and Handheld Instruments Diagnostic Equipment ORDERING Call toll free 800 979 2020 US and Canada 610 889 0200 International 31 0 485 350300 Europe Monday thru Friday 8 30AM 8PM EST Fax 610 889 3233 Email info accutome com Web www accutome com SHIPPING Ground Via UPS Ground Service Air Via best method Saturday Orders must be placed before 3PM EST Friday to ensure ...