Accu-Steam™ G2 Gas Service Manual
18
SP8042-1911
Digital Control Board
AT0E-3625-5-R** (R** refers to software
revision of board programming).
• Receives input signal from RTD
Temperature Sensor.
• Sends DCV output signal to Control
Relay coil which controls igntion
module.
Fuse .75 Amp 250v
AT0E-2731-4
• The .75A fuse is to provide protection
to the control circuitry in case of a
short in the system.
Hi-Limit Control Board
AT0E-3880-2
• Receives input signal from Hi-Limit
RTD temperature sensor
• Cuts power to ignition module and
pilot valve when unsafe signal is met
from Hi-Limit RTD (approximatively
425° or 1820
Ω
)
Temperature Sensor RTD
AT0E-5062-1 (1000 OHM)
• The RTD provide temperature
reference information to the
Temperature Control. This RTD is a
1000
Ω
.
Hi-Limit Temperature Sensor, RTD
AT0E-5062-1 (1000 OHM)
SN 18182 and above
(When replacing under SN 18181, order
kit AT2A-5063-1).
• The RTD provides temperature
reference information to the Hi-Limit
Board. When replacing under SN
18181, order kit AT2A-5063-1, if over
SN 18182, use part AT0E-5062-1.
Heat Lamp 24v Red
AT0E-1800-2
• Receives 24VAC power from the
ignition module and indicates the
valve is open.
Hi-Limit
RTD
Temp Sensor
RTD
Igniter
Fuse Block
Transformer
Fault Timer
Hi-Limit Control
board
Ignition Control
Module
Main Control Board
Control
Relay
Control Valves
Tap
Fig 6.A
Содержание Accu-Steam G2 Series
Страница 34: ......