Страница 1: ...User Manual for and all products with a Digi white Digital Readout Firmware version P1 040 Higher Digi Scale Digi Scale Model 10 Model 20 ...

Страница 2: ...ness for a particular purpose except as expressly provided in this agreement Accurate Technology Inc shall not be liable for any special incidental or consequential damages or for loss damage or expense directly or indirectly arising from the customer s use of or inability to use the equipment either separately or in combination with other equipment or for personal injury or loss or destruction of...

Страница 3: ...4 Digi Scale Specifications 4 Section 2 Digi Scale 10 5 Shortening Scales 7 Section 3 Digi Scale 20 8 Section 4 Readout Operation 10 Readout Keys 10 Timing 10 ON OFF 10 MODE 10 0 and Keys 11 Changing Resolution 11 Incremental Measurements 11 Lock Mode 11 Reverse Scaling 12 Changing the Batteries 12 Jumpers 13 Frequently Asked Questions 14 ...

Страница 4: ...general purpose measuring applications requiring digital precision low cost battery power and reliable operation For more demanding applications Accurate Technology ProScale ABS should be considered Some differences are Feature Digi Scale ProScale ABS Technology Incremental Absolute Measuring Range 6 60 in 10 in to 20 ft Accuracy 010 in 002 in ft Repeatability 010 in 001 in Encoder length 6 feet u...

Страница 5: ...can be installed on or used in many types of equipment or applications all installations are a little different Therefore it s the responsibility of the installer to choose bolts screws or other mounting hardware that guarantees proper installation Note If you ordered a Digi Kit product that contains instructions for installation on or for a specific product ie Digi Fence or Digi Stop follow those...

Страница 6: ... surface is excessively uneven you may need to use washers or spacers to ensure a good mount Scale Scale Up For Positive Readings Encoder Scale Up For Negative Readings Scale Down For Negative Readings Scale Down For Positive Readings 3 Note the orientation of the Encoder When the side with two screw holes is on the right moving the scale up produces positive readings and moving the scale down pro...

Страница 7: ...arget device Be sure both connections are secure or inaccurate scale readings can occur 6 Take care when sliding the scale into the Encoder so the brass fingers inside the Encoder do not get damaged A slight wiggling motion when installing the scale into the Encoder will simplify the process Note If your application requires a scale of a different length see SHORTENING SCALES ...

Страница 8: ...ged if not cut properly 1 Clamp the wires so they do not pull away from the extrusion 2 Using a hacksaw cut through the aluminum extrusion 3 Use a file or sanding tool to chamfer the cut end to approximately the specifications shown in the illustration 4 Remove all burrs 5 Test the shortened scale by sliding a Encoder on There should not be any binding Wires 25 6mm 07 2mm Wires ...

Страница 9: ...instructions rather than the instructions presented here 1 Determine an appropriate mounting location for the Digi Scale The scale should be mounted to a stationary part of the device The Encoder then slides along the scale using the supplied guide clip to transfer movement to the Encoder The Readout should be mounted in a location which allows for easy viewing by the operator The location of the ...

Страница 10: ...nstalling the Encoder on the scale will simplify the process 5 Slide the Encoder until it meets and engages with the guide clip Check that the guide clip exerts sufficient pressure on the Encoder as seen in the figure below 6 Place the cable in a secure position Do not leave the cable where it could be damaged or pulled from the Encoder Plug the Encoder into the Readout Note If any other mounting ...

Страница 11: ...15 minutes the Digital Readout will automatically turn itself off to conserve battery life While off if a position change is detected 05mm or 002in or the ON OFF button is pressed the Readout will automatically turn itself on with no loss of measurement information MODE The digital Readout can show measurement information in the customary measurement system Imperial or the Metric system To change ...

Страница 12: ... jumpers To display high resolution place JP2 in the A position To display normal resolution place JP2 in the B position Incremental Measurements To make Incremental measurements press and hold MODE key for approximately 3 seconds This switches the Readout to INCremental mode as shown on the LCD You can now press the ZERO or keys if desired Any measurement taken will be an incremental measurement ...

Страница 13: ...e Encoder in the opposite direction being careful not to damage the ground fingers inside the Encoder 2 Change the position of jumper JP1 on the Readout circuit board Changing the Batteries A BAT indicator will appear in the upper left corner of the LCD display when new batteries are needed Remove the screws in the upper right and lower left corners Pull the cover off Remove the old batteries Rein...

Страница 14: ...Common One end pin is labeled A and the other end pin is labeled B JP1 Reverse Scaling Changes the direction of readings JP2 Resolution Position A 001in 01mm high resolution Position B 01in 1mm normal resolution fractions remain the same in both settings 1 16 1 32 164 JP3 FACTORY USE ONLY JP1 JP3 JP2 No longer applicable starting with version P1 040 ...

Страница 15: ...essed and the combination of the keys pressed is important This manual uses the term momentarily to describe a key press of typically less than 1 second Whereas press and hold is used imply a key press of typically longer than 1 5 seconds As an example when using a PC keyboard to type a capital letter you would press and hold the SHIFT key and momentarily depress the LETTER key In addition keep in...

Страница 16: ...Accurate Technology Digi Scale Page 16 of 17 ...

Страница 17: ...duct Please register your system at http www proscale com registration htm Accurate Technology Inc 270 Rutledge Rd Unit E Fletcher NC 28732 USA 800 233 0580 828 654 7920 Fax 828 654 8824 www digi kit com customerservice accurate technology com This manual is available online at www digi kit com ...