ACCURATE ELECTRONICS 104001C Скачать руководство пользователя страница 1

 

 

 

 

 

Page  1 of 10 

 

 

 

 

Model  104001C 

 

 

 

 

                           January 2014 

This document contains proprietary information and is supplied for identification, maintenance, engineering evaluation or inspection purposes only and shall not be duplicated or disclosed without written 
permission of:  ACCURATE ELECTRONICS INC By accepting this document the recipient agrees to make every effort to prevent unauthorized use of this information. 

Prac_104001C0_RevB.pdf 

Contents: 

 

 

 

 

 

 

Section 1.  General 

 

 

 

Section 2.  Application 

 

 

 

Section 3.  Installation 

 

 

 

Section 4.  Circuit Description 

 

 

Section 5.  Mechanical Outline 

 

 

Section 6.  Specifications  

 

 

Section 7.  Testing and Troubleshooting   

Section 8.  Maintenance   

 

 

Section 9.  Warranty 

 

 

 

 
Figure 1.  Circuit Description 

 

 

Figure 2.  Mechanical Outline 

 

 

10 

Figure 3.  Typical Off-Premise-Station (OPS) 
 

   Circuit Using 104001C Line Amplifiers  2 

Figure 4.  Module Arrangement for Two  

   4Wire 6Way Resistive Bridges in an 
   Accurate 246 Mounting Assembly 

Figure 5.  Typical 4Wire DX Signaling 

   Application Using 104001C 

 

   Line Amplifiers 

 

 

Figure 6.  4000C 1 Option Switch and  

   Strap Locations 

 

 

  
Table 1.   Typical Transmit and Receive 

  Equalization Frequency Response 

Table 2.   Terminating Impedance Selection 

  Guidelines 

 

 

 

Table 3.   Externals Connections to 104001C 

Table 4.   Equalized Gain Settings From 

  Cable Loss Data 

 

 

Table 5.   Test Guide Checklist 

 

 

 

1.  GENERAL 

1.01

  This practice provides application, specification, circuit and mechanical 

description,  maintenance,  installation,  and  warranty  information  relating  to 
Accurate Electronics’ Prescription Line Amplifier, Model 104001C. 

1.02

  The 104001C Prescription Line Amplifier module ( Figure 1) provides 

active prescription level control, active prescription amplitude equalization, 

and  impedance  matching  for  the  transmit  and  receive  channels  of  a  4wire 
voice-frequency  transmission  facility.    The  104001C  also  contains  two 
independent sealing-current sources, one on the facility side and the other on 
the terminal side of the module. 

Note:    Because  the  104001C  has  identical  equalizers  in  both  cannels, 
identical  impedance-matching  capabilities  at  all  four  ports,  and  identical 
sealing-current  sources  on  the  facility  and  terminal  sides,  it  can  be  used 
either  at  an  intermediate  point  or  near  an  end  point  of  a  4wire  facility.  
Although the terms “facility side” and “terminal side” do not strictly apply 
in  intermediate  applications,  these  terms  will  for  convenience,  be  used 
throughout this practice as follows:  Facility side will refer to the receive-
input, transmit-output side of the 104001C, and Terminal side will refer to 
the transmit-input, receive-output side as shown in Figure 1.  of this practice. 

1.03

    This  practice  section  is  reissued  to  cover  the  Issue  4  version  of  the 

104001C module (Accurate Electronic part number 104001C).  The Issue 4 
Module  is  identical  to  its  Issue  3  predecessor  except  for  the  addition  of  a 
front-panel power-on indicator LED. 

1.04

    The  4001C’s  transmit  and  receive  amplifiers  can  be  independently 

prescription-set to provide from 0 to 24dB of  loss  or 0 to 24dB of gain in 
their  respective  channels.    For  each  channel,  gain  or  loss  is  selected  via  a 
front-panel  slide  switch.    The  desired  amount  of  gain  or  loss  is  then 
introduced into each channel in precise 0.1dB increments via a front-panel 
DIP  switch.    The maximum  output  level  of  each  channel  is +10dBm,  with 
distortion at maximum output less than 1 percent.  

1.05

    All  four  ports  of  the  104001C  module  can  be  switch-optioned  for 

balanced 1200, 600, or 150-ohm terminating impedance.  The impedance of 
the  two  facility-side  ports  is  selected  independently  from  that  of  the  two 
terminal-side  ports.    The  transformers  at  all  four  ports  of  the  module  are 
center-tapped to derive balanced simplex leads. 

1.06

  In addition to active prescription level-control circuitry, the 104001C 

contains  active  prescription  slope-type  amplitude-equalization  circuitry  in 
both  channels.  The  transmit  and  receive  equalizers  are  identical,  each 
providing from 0 to 7.5dB of gain at 2804Hz (re 1004Hz).  Equalization is 
introduced  into  each  channel  independently,  in  0.5dB  increments,  via  DIP 
switches on the module’s front panel. 

1.07

  The 104001C can be optioned to provide 25mA of internally generated 

sealing current to metallic facilities on the facility and terminal sides of the 
module, to accept externally generated sealing current from the far ends of 
the facilities on both sides of the module, to derive normal simplex leads on 
both sides of the module, or to provide bypassed (straight-through) simplex-
lead signaling via a path separate from the transmit and receive transmission 
paths.    Each  of  the  104001C’s  two  internal  sealing-current  sources  has  a 
“ZAP” feature by which a greater amount of sealing current is provided for a 
few seconds when power is initially applied to the module. 

1.08

    The  front  panel  of  the  104001C  is  designed  so  that  all  level  and 

equalization adjustments can be made while the module is mounted in place.  
Six front-panel bantam-type test jacks facilitate alignment and maintenance.  
Both  bridging  and  opening  jacks  are  provided  at  the  facility-side  ports; 

ACCURATE ELECTRONICS INC 

PO BOX 1654  97075-1654     8687 SW HALL BLVD   97008      BEAVERTON OR  USA     503.641.0118     FAX 503.646.3903 

 

WWW.ACCURATE.ORG

 

Practice Section 10model Rev B 

      

PRESCRIPTION LINE AMPLIFIER 

MODEL 104001C 

 

Содержание 104001C

Страница 1: ...to the transmit input receive output side as shown in Figure 1 of this practice 1 03 This practice section is reissued to cover the Issue 4 version of the 104001C module Accurate Electronic part numb...

Страница 2: ...mounted across a 23 inch rack The 104001C can also be used in the Accurate 246 Resistive Data Bridge System in which case the module mounts in one position of the Accurate 246 Mounting Assembly The 2...

Страница 3: ...n both the facility and terminal sides the 104001C can interface a variety of facilities and equipment as listed in Table 2 The 150 ohm options provide a small amount of slope equalization for long se...

Страница 4: ...lf position Pin numbers are found on the body of the connector TABLE 3 External Connections to 104001C CONNECT To PIN XMT OUT TIP 41 XMT OUT RING 47 XMT OUT SIMPLEX 43 and 45 RCV IN TIP 7 RCV IN RING...

Страница 5: ...rement is expressed as EMG both the transmit and receive portions of the transmission measuring set TMS used for alignment must be optioned for 600 ohms Receive Channel 1 Determine from the CLR whethe...

Страница 6: ...terminated measurement at the terminal side interface impedance selected on the module Connect the receive portion of the TMS to the module s RCV OUT jack The transmit portion of the TMS must remain d...

Страница 7: ...slope type amplitude equalizer consisting of the EQUALIZATION ADJUST circuit and EQL AMP The EQUALIZATION ADJUST circuit is controlled by the channel s front panel EQL switches These switches allow se...

Страница 8: ...ate for repair or replacement as directed below We strongly recommend that no internal component level testing or repairs be attempted on the module Unauthorized testing or repairs may void the module...

Страница 9: ...ve Equalization Maintain connections as above Adjust RCV EQL switches for no equalization all switches set to out Adjust module s receive output level for 0dBm at 1004hz Change input frequency to 2804...

Страница 10: ...document contains proprietary information and is supplied for identification maintenance engineering evaluation or inspection purposes only and shall not be duplicated or disclosed without written pe...