1. ON/OFF:

2. ZERO/TARE:

3. “F” Key:

4. CAL/PRINT:

5. LIGHT :

Press to turn scale ON or OFF.

Pushing ZERO/TARE key “zero’s” display, pushing and holding ZERO/TARE key for more than 3 
seconds accesses application menu.

Function key for applications (Unit toggling, Counting & Totaling ) and menu scrolling.

Press and “hold” CAL/PRINT key (for approximately 3 seconds) and scale will automatically enter 
calibration mode (displaying one of three weight values). Press and “release” CAL/PRINT key to print 
displayed information when utilizing RS-232 interface.   

Turns on backlight during battery operation (Auto Off: One Minute).

ENGLISH

2

Key Functions / Description:

Calibration:

Weight Calibration:

 

with the pan cleared and zero stability indicated in display, press and hold the 

“CAL/PRINT” key for more than 3 seconds to enter the calibration mode.
Depending upon your Model a default weight will be displayed in “kg” (note: you have 3 weight values 
to choose from)
In order to select additional cal-weight options, press and release the “F” key and the display will 
toggle between selectable values based on model. (Please see Product Specifications)
After selection of the desired cal-weight option, press the “CAL/PRINT” key and release to confirm, 
and the value will flash to begin calibration.
Place corresponding weight onto center of pan. If weight is accepted, the display will stop flashing and 
show “selected kg” value in display. 

1

2

3

4

5

ON / OFF

TARE / ZERO

F

CAL / PRINT

LIGHT

1.

2.

3.

4.

5.

Содержание SVI-100E

Страница 1: ...PROFESSIONAL PRECISION INDUSTRIAL SCALE SVI SERIES SVI 50C SVI 100E SVI 200F SVI 10A SVI 20B...

Страница 2: ...ion Programs Features Care Maintenance Menu Settings Scale Operating Manu Interface Description Product Specifications AC Adapter Battery Operation On Off Cal Print F Key Zero Tare Light Weight Unit C...

Страница 3: ...recommended to remove battery when scale is not in use for extended periods Also replace low or dead batteries Note Back lit display is off unless activated with Light key ACAdapter Battery Operation...

Страница 4: ...cription Calibration Weight Calibration with the pan cleared and zero stability indicated in display press and hold the CAL PRINT key for more than 3 seconds to enter the calibration mode Depending up...

Страница 5: ...t options g lbs ozt kg depending upon model Select desired weigh unit by pressing CAL PRINT selected option will be displayed and balance will return to weighing mode Pressing the F key will enable yo...

Страница 6: ...th water or cleaning liquids Please use supplied packaging when transporting scale Remember to remove battery when not in use 1 2 3 5 4 Totaling To select the application Totaling press and hold TARE...

Страница 7: ...ore selected codes and exit menu press and hold ZERO TARE key for 3 seconds or until display returns to weigh mode 6 8 7 9 Unit Toggling Auto Zero Calibration Setting Baud Rate Parity 141 Unlocked 0 1...

Страница 8: ...Totaling Mode Calibration Mode ASCII p t u f a b c D HEX 70 0D 0A 74 0D 0A 75 0D 0A 66 0D 0A 61 0D 0A 62 0D 0A 63 0D 0A 64 0D 0A CR LF CR LF CR LF CR LF CR LF CR LF CR LF CR LF Output Format Position...

Страница 9: ...ozt 100 kg 220 lbs 3215 ozt 200 kg 440 lbs 6430 ozt 1 g 0 001 kg 0 002 lbs 0 05 ozt 2 g 0 002 kg 0 005 lbs 0 1 ozt 0 005 kg 0 01 lbs 0 2 ozt 0 02 kg 0 05 lbs 0 5 ozt 0 05 kg 0 1 lbs 1 ozt grams kilog...

Страница 10: ...Zone 100102 Bejing PR China TEL 86 10 6439 2233 If you have any questions please contact your local Acculab supplier visit our website www acculab com or contact Si tiene alguna duda p ngase en contac...

Отзывы: