26 

 

Troubleshooting 

 When Error occurs, the front use button (ICE-WATER-ICE & WATER) of the door lights alternately to 

the left and right. Restart after action. 

 

 When the button is lit alternately to the left and right, open the door and press the bottom setting 

button of the control buttons, Error display will appear. 

 

Display 

Error type 

Causes 

Action 

Release 

Operation 

Er01 

Evaporator 
temperature 
error 

When the Evaporator 
temperature is 0 ° C or 
more after 30 minutes 
passed during the ice 
making 

Check refrigerant 
leakage 
Check sensor and 
attachment 
abnormality 

Resupply 
power 
after 
resolving 
cooling 
problem 

Stop ice making 

Er03 

Evaporator 
temperature 
error 

When the Evaporator 
temperature is over -5 ° 
C after 30 minutes 
passed 

Check refrigerant 
leakage 
Check sensor and 
attachment 
abnormality 

Resupply 
power 
after 
resolving 
cooling 
problem 

Keep on 
ice making 

Er06 

Temperature 
sensor error 

Displayed when 
temperature sensor is open 
or shorted. 

Check sensor and 
attachment 
abnormality 

Start operation 
after 
sensor 
part repair 

Stop ice making 

Er07 

Temperature 
Sensor Error 

Occurs when the 
temperature sensor of COND 
OUT 
(F11) is broken 
(All operations will be stopped 
and 
the "water" dispensing mode 
will be activated) 

Check sensor 
and 
attachment 
abnormality 

Start 
operation 
after sensor 
part 
repair 

Stop ice 
making 

Er13 

High 
pressure 
switch error 

Condenser dust, fan 
motor failure, cold cycle 
abnormality, etc. 

Remove dust, 
Check Fan motor 
Check for 
abnormal cold 
cycle 

Automatic 
return after 
action 

Stop 
compressor. 
Stop motor 
after operating 
10 
seconds. 

Er14 

High 
pressure 
switch error 

Occurs when High 
pressure switch is OPEN 3 
times or more 

Contact service 
representative 

Start 
operation 
after action 

Stop 
compressor. 
Stop motor 
after operating 
10 
seconds. 

Er15 

Water 
supply error 

When water level is not 
detected by the water 
level sensor due to no 
water 
supply for 120 seconds. 

Water supply 
pressure check 
Water level 
sensor check 

Start 
operation 
after action 

Stop ice making 

Содержание AIWD160

Страница 1: ...450 User s Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS FELIX STORCH INC Summit Appliance Division An ISO 9001 2015 registered company 770 Garrison Avenue Bronx...

Страница 2: ...tart the product 15 17 Button operation 15 Function button description FND display window 16 Three drainage functions forced drainage automatic draining water drainage 17 Stop switch 17 Product Mainte...

Страница 3: ...h CAUTION means that failure to heed this safety statement may result in minor or moderate personal injury or property or equipment damage What you must obey Prohibited Disassembly Prohibited No Conta...

Страница 4: ...or disconnect power before cleaning or servicing Failure to do so can result in electrical shock or death Do not attempt to repair or replace any part of your ice dispenser unless it is specifically r...

Страница 5: ...g the power cord to stop operation If you continue operating in abnormal conditions there is a risk of fire or electric shock Do not use Do not use if the outlet is loose or has a problem There is a r...

Страница 6: ...SIG 193 PSIG 150 PSIG Compressor LRA 40A LRA 20A LRA 53A Fan Motor 115 V 0 7 A 115 V 1 1A 115 V 0 2A Geared Motor 115V 1 6A 115V 1 6A 115V 1 6A Maximum Fuse Size 20A 15A 20A Max HACR Breaker USA Only...

Страница 7: ...7 Location of Parts AIWD282 SCIWD282 Front Top Bottom...

Страница 8: ...8 Location of Parts AIWD450 Front Rear Top Bottom...

Страница 9: ...9 Location of Parts AIWD160 Front Rear Top Bottom...

Страница 10: ...F Allow enough ventilation For normal operation install the dispenser at least 4 inches away from the back wall and 6 inches above the top of the dispenser Never block the upper vents and do not plac...

Страница 11: ...re chemically combined with water molecules These impurities are called dissolved solids The mineral content of the ice produced by the dispenser is reduced compared to the content in the water before...

Страница 12: ...to make sure the outlet is properly grounded When a standard 2 prong wall outlet is encountered it is your responsibility and obligation to have it replaced with a properly grounded 3 prong wall outl...

Страница 13: ...the lower set screws of the drain box then loosen the set screws on the top of the front panel and pull out the front panel taking both sides 3 Side panel Open the door loosen the screws on the top of...

Страница 14: ...oduct as shown in the picture and secure the clip to prevent hose detachment After the installation is complete please operate the product and check whether there is leakage in the water supply and dr...

Страница 15: ...sappear when restarting after the action against the ERROR Service cycle setting notification parts check replacement cycle notification If the motor is running for more than 10 000 hours the correspo...

Страница 16: ...KING switch is operated FND 1st 2nd digits drain time 2 seconds oF 9 seconds Set Unit of one second FND 3rd 4th digits drain interval 1 0 hour 0 5 9 5 hours every 30 minutes F 6 ICE WATER volume contr...

Страница 17: ...n interval 1 0 hour 0 5 to 9 5 hours every 30 minutes Initial water draining function F 4 Turn the power switch off and then on again the ICE MAKING OFF WASH switch at ICE MAKING position to operate t...

Страница 18: ...at the same time for 3 seconds with any signal on the FND window Forced drainage will be done for 30 seconds 2 Turn off the power switch and disconnect the power plug from the outlet 3 Remove the uppe...

Страница 19: ...o not touch or disassemble the parts of the ice maker Before service Turn off the power switch of the dispenser and the earth leakage breaker and disconnect the power plug from the outlet Choking haza...

Страница 20: ...seal bolt 1 Check for leaks around the seal bolt Tighten if necessary and replace O rings 2 Always replace the O ring when loosening the seal bolt and tighten it again If there is no O ring apply Loc...

Страница 21: ...eel and rust generated in contact with stainless steel and ordinary iron products during storage It should be removed with neutral detergent at the first sign of rusting If the rusting state is furthe...

Страница 22: ...er Clean the level sensor with washing solution Wash the water level sensor thoroughly with clean water Fix the level sensor to the correct position 9 Switch the ICE MAKING OFF WASH switch to the ICE...

Страница 23: ...MAKING OFF WASH switch to the WASH position and let the remaining water drain out for 5 minutes 13 Turn the power switch to OFF and disconnect the power plug from the outlet Disinfection procedure fi...

Страница 24: ...24 Circuit Diagrams AIWD282 SCIWD282 AIWD450...

Страница 25: ...25 Circuit Diagrams AIWD160...

Страница 26: ...or Displayed when temperature sensor is open or shorted Check sensor and attachment abnormality Start operation after sensor part repair Stop ice making Er07 Temperature Sensor Error Occurs when the t...

Страница 27: ...op ice making Er20 Cover error When the outlet cover is open Cover closed Operation after action Stop dispensing Er25 Motor restraint Occurs when Evaporator inlet outlet temperature is 18 or less for...

Страница 28: ...28 NOTES...

Страница 29: ...4 Is the water supply valve operating After confirming contact A S center 3 Ice freezes too late 1 Machine is too dirty lots of dust Air cooled After removing the front cover remove the dust net to t...

Страница 30: ...t approved bywarrantor 4 Replacement parts or repair labor costs for units operated outside the United States 5 Repairs to parts or systems resulting from unauthorized modifications made to the applia...