5. Bill Rejection Codes Descriptions
During the count, suspicious bills are rejected directly into the rejection
pocket. To determine the specific cause of rejection, simply press the
key and the display will show the rejection details using the following error
codes described below:
•
TYPE 1: Communication failure between Image Software and Control
Software.
•
IMAGE: The CIS was unable to identify the rejected bill.
•
MT: Rejected for suspicious Metal Thread.
•
UV: Rejected for suspicious Ultraviolet.
•
MG: Rejected for suspicious Magnetic Ink.
•
IR: Rejected for suspicious Infrared.
•
DOUBLE: Rejected because two bills passed stuck together.
•
CHAIN: Chaining problems (adjust the gap thickness screw).
NOTE:
When a unit reports multiple CHAIN events, the thickness
calibration must be checked before taking other measures. Poor thickness
calibration also affects the unit in other aspects of its operation.