Accu-Scope EXC 350 Скачать руководство пользователя страница 1

 

 

      MANUAL 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

 

 

 

73 Mall Drive, Commack, NY  11725  •  631-864-1000 (P)  •  www.accu-scope.com  

LED 

Fluorescence 

Illuminator

 

 

 

Содержание EXC 350

Страница 1: ...MANUAL 73 Mall Drive Commack NY 11725 631 864 1000 P www accu scope com LED Fluorescence Illuminator...

Страница 2: ...CU SCOPE 73 Mall Drive Commack NY 11725 631 864 1000 www accu scope com 2 CONTENTS SPECIFICATIONS 3 IN THE BOX 3 COMPONENTS 4 INSTALLATION INSTRUCTIONS 5 OPERATION INSTRUCTIONS 8 TROUBLESHOOTING 10 AT...

Страница 3: ...pecifications Please contact your ACCU SCOPE dealer if you have other requirements special orders may be available SPECIFICATIONS STANDARD FLUORESCENCE CHANNEL SPECIFICATION Excitation Color Excitatio...

Страница 4: ...luminator Right Side View Illuminator Bottom View Upper dovetail receiver Lower dovetail on underside Main power Viewing head set screw UV light shield mounting screws Fluorescence channel selector LE...

Страница 5: ...our illuminator may vary slightly in appearance than the one used to illustrate the following procedures 1 Loosen the set screw that secures the head to the frame Note that some microscopes have a thu...

Страница 6: ...he dovetail does not fully enter the receiver you may need to loosen the set screw some more 6 When aligned tighten the set screw on the microscope frame to secure the illuminator to the frame 7 With...

Страница 7: ...If the dovetail does not fully enter the receiver you may need to loosen the set screw some more 9 When aligned tighten the set screw on the illuminator to secure the viewing head to the top of the il...

Страница 8: ...r to the unit is off LED intensity control knob has two functions o Rotate the knob to increase or decrease the LED intensity for that fluorescence channel o Press the knob to turn off the LED Press a...

Страница 9: ...O is used for both UV fluorescence observation of DAPI or similar UV fluorophores and it is also used for brightfield observation To use the UV O position for brightfield press the LED intensity contr...

Страница 10: ...tted light for brightfield has been turned off 4 Lower the condenser position and close the condenser aperture diaphragm This will reduce or eliminate autofluorescence from the transmitted light lamph...

Страница 11: ...orrect power adapter is used LIMITED WARRANTY This illuminator the LED lamp and its electronic components are warranted to be free from defects in material and workmanship for a period of one year fro...