This boiler works with built-in full pre-mixing gas burner and can be supplied in the versions:
-
Play Entry
: sealed room condensing boiler and forced draft for the production of hot water for heating and instantaneous production of
hot water for domestic use;
The boilers come in the following thermal capacity versions:
- Play Entry Entry 20 : with a thermal capacity of 20 kW (heating) and 24 kW (domestic)
All models are equipped with electronic ignition and ionization-based flame control.
The boilers meet all standards in force in the country of destination, which is indicated on the technical data plate.
The installation in a country other than the specified ones may lead to damage to people, animals and/or objects.
The main technical features of the boiler are the following:
Construction Characteristics
- The control panel with IPX4D protection degree of the electric
system.
- Integrated safety and modulation electronic board security.
- Electronic ignition with embedded igniter and ionization-based
flame detection.
- Full pre-mixing burner made from stainless steel.
- High-efficiency single temperature heat exchanger made from
stainless steel and aluminium.
- Double-shutter gas valve electronically modulated with constant
air/gas ratio.
- Modulated combustion fan with electronic control of the correct
operation.
- Highly effective modulated heat circulator with built-in air drain-
age.
- Heating circuit pressure sensor.
- Temperature probe for the heating and domestic use water.
- Fumes probe at the outlet
- Integrated automatic by-pass.
- 9-litre expansion tank.
- Manual valves for system feeding and draining.
- Stainless steel plate heat exchanger for domestic hot water (only
in the Play Entry version).
- Motor-controlled divert valve.
- Flow meter for domestic use hot water.
User interface
- Built-in LCD interface for the displaying and controlling of the boil-
er operation mode: OFF, UNLOCK, WINTER and SUMMER.
- Heating water temperature regulator: 20-80°C (standard range) or
20-47°C (low range).
- Adjustment of the hot water temperature for domestic use: 10-
60°C.
Operation specifications
- Electronic modulation of the flame in the heating function with
ramp-up timing.
- Electronic modulation of the flame in the domestic use function.
- Domestic function priority.
- Antifreeze function on the delivery line: ON at P38 + 2°C; OFF at
P38 + 5°C.
- Antifreeze function on the domestic hot water line: ON at 5°C;
OFF at 7°C.
- Boiler antifreeze function (Play Entry SV + external boiler option
with NTC probe): ON at 5°C; OFF at 7°C.
- Timed chimney sweep function: 30 minutes.
- Maximum thermal capacity adjusting parameter for the heating
and domestic hot water functions.
- Ignition thermal capacity adjusting parameter.
- Heating pre-selection range: standard or low.
- Flame propagation during ignition function.
- Heating post-circulation function: 120 seconds (adjustable).
- Post-circulation function for the domestic hot water use circuit:
30 seconds.
- Post-circulation function for heating temperature > 90°C: stop
when T < 88°C.
- Post-ventilation function after operation: 30 seconds.
- Post-ventilation function for heating temperature > 99°C: stop
when T < 93°C.
- Circulator and diverter valve anti-blocking function: 30 seconds of
operation after 24 hours of shut-down.
- Prearranged for the connection to a room thermostat.
- Ready for operation with external probe (option supplied by the
manufacturer).
- Ready for operation with remote control OpenTherm (option sup-
plied by the manufacturer).
- Ready for area-based operation.
- Anti-water hammer function: adjustable from 0 to 3 seconds using
the parameter P26.
2. Technical data and dimensions
2.1. Technical features