3: Management & Configuration
SNMP trap configuration parameters
Enable trap
Enable this option to have the unit send SNMPv1 or SNMPv2c traps to a specified notification receiver.
Notification receiver
Specify the IP address or host name of the device that will receive SNMP traps (and/or inform notifications). The unit
sends a Cold Start trap when it starts up.
Community string
Specify the community string required to send traps to the notification receiver.
Host UDP port
Specify the UDP port that the unit will use to send traps to the notification receiver. By default, the well-known SNMP trap
port (162) is used.