3: Management & Configuration
SNMP parameters
Enable Agent
Select this checkbox to enable the SNMP agent.
Use host name as system name
Select this checkbox to use host's name as system-name.
SNMP system name
Specify a name to identify the unit. By convention, this is the node's fully-qualified domain name.
Contact information
Specify contact information for the unit. Generally an email address.
System location
Identify the physical location of the unit.
Agent UDP port
Specify the UDP port the SNMP agent uses for all IPv4 interfaces.
Note: Changing this value restarts the SNMP agent.
Read-Only community
Specify the community string to control read-only access to the unit.
Read-Write community
Specify the community string to control read/write access to the unit.
Enable authentication trap generation
Enable this option to have a trap generated when authentication to the agent fails.