background image

USER MANUAL

USER MANUAL

AIRLIFT SERIES

SHUTTER EXHAUST FAN SYSTEM

Содержание AC-ALT10

Страница 1: ...USER MANUAL USER MANUAL AIRLIFT SERIES SHUTTER EXHAUST FAN SYSTEM ...

Страница 2: ......

Страница 3: ...roduct quality and friendly customer service If you have any questions or suggestions please don t hesitate to contact us Visit www acinfinity com and click contact for our contact information EMAIL support acinfinity com WEB www acinfinity com LOCATION Los Angeles CA ...

Страница 4: ...30 AC ALT36 UPC A 819137020900 819137020917 819137020924 819137020948 819137020948 819137020955 819137020962 819137020986 819137020993 MANUAL CODE AL1904X1 SERIOUS INJURY OR DEATH Please do not touch the fan s impeller and blades Secure all nearby objects including wires and cables from coming into contact with the fan s impeller and blades Use caution when deciding where to install this fan ...

Страница 5: ...5 MANUAL INDEX Manual Index Key Features Product Contents Mounting Powering Programming Other AC Infinity Products Warranty Page 5 Page 6 Page 7 Page 8 Page 12 Page 13 Page 21 Page 22 ...

Страница 6: ...FICIENT EC MOTOR PWM controlled EC motor enables precise speed control low noise and higher energy efficiency ALUMINIUM SHUTTERS Closes when fans are not running to prevent dust and unwanted elements from entering DUAL BALL BEARINGS Long life bearings rated at 67 000 hours Also allows the fan to be mounted in any direction WEATHERPROOF The shutter fan unit is sealed to Ingress Protection 44 standa...

Страница 7: ...7 PRODUCT CONTENTS AIRLIFT SHUTTER FAN SYSTEM Included in all series SENSOR PROBE x1 UNIVERSAL CONTROLLER x1 SHUTTER FAN UNIT x1 WOOD SCREW x4 WIRE TIES x4 MACHINE SCREW x4 CONTROLLER SCREW SET x2 ...

Страница 8: ... higher in the room to exhaust out heated air which will rise on its own due to natural convection STEP 2 Measure the dimensions of the shutter fan s mounting frame which will go through the wall Select a location on the wall where you will be mounting the fan Please make sure that the wall is free of any wires or pipes Using the measurements of the shutter fan use a level and ruler to draw an out...

Страница 9: ...an unit Then using a drill bit create the four mounting holes STEP 3 Depending on your mounting surface material use the appropriate tools to cut into the wall Use a drill or a hand saw to create an opening large enough to insert a saw blade or jigsaw inside the outlined area of the wall panel Thinner Woods or Plastic Woods Tougher Plastic or Metal ...

Страница 10: ...ke sure the controller connectors and power cord is on the inside of the room Then use the included hardware to secure the fan STEP 6 Once the fan is mounted securely you can then mount the controller using the included hardware Place the controller near the fan in order to power the controller Inside ...

Страница 11: ...probe head near by preferably in the hottest area of the room You can use the wire tie to secure the probe away from the fan blades STEP 1 Locate the connector plug of the thermal probe and plug it into the bottom of the thermal controller ...

Страница 12: ...ller plug the fans power cord into an AC power outlet STEP 3 Connect the molex end from the fan into the bottom of the controller Be sure to plug it into the left molex 4 pin connector that has the power and fan icon this plug is meant to power the controller ...

Страница 13: ...luding alarms and screen lock 9 SETTING Displays the value you have set for the current mode Press the up or down button to change 7 PROBE HUMIDITY Displays the current humidity that the corded sensor probe is measuring Shows if no probe is plugged in 5 CONTROLLER MODE This area displays the mode that the controller is currently in Press the Mode Button to cycle through the modes 3 LEAF BUTTON Thi...

Страница 14: ...play s units F or C PROGRAMMING MODE SETTING Press the Mode button to cycle through the controller s available programming modes and settings ON Mode OFF Mode TIMER Mode AUTO Mode 4 triggers ALARM Settings 4 settings TIMER MODE In this mode press the up or down button to set a time for the timer The fans will run at the speed set in ON Mode until the timer s clock runs out in which the fans will s...

Страница 15: ... this mode press the up or down button to set a low temperature trigger The fans will activate if the probe s measured temperature falls below the temperature you have set in this mode The activated fans will slowly increase in speed until it reaches the speed set in ON Mode Whenever the measured temperature rises above your set temperature the fans will slowly decrease in speed until the fans sto...

Страница 16: ...this mode press the up or down button to set a low humidity trigger The fans will activate if the probe s measured humidity falls below the humidity you have set in this mode The activated fans will slowly increase in speed until it reaches the speed set in ON Mode Whenever the measured humidity rises above your set temperature the fans will slowly decrease in speed until the fans stop You may als...

Страница 17: ...alarm triggers can only activate in AUTO ON or TIMER Mode Please leave ALARM SETTING to arm the controller ALARM SETTING LOW TEMP In this settings mode press the up and down button to set a low temperature alarm The alarm will activate if the probe s measured tem perature falls below the temperature you have set in this mode When the alarm triggers the fan will start spinning at max speed regardle...

Страница 18: ...LOW HUMID In this settings mode press the up and down button to set a low temperature alarm The alarm will activate if the probe s measured tem perature falls below the temperature you have set in this mode When the alarm triggers the fan will start spinning at max speed regardless of your other settings You may also hold the up and down button simultaneously to turn off this alarm in which the di...

Страница 19: ...To adjust the temperature that the probe sensor is measuring please press the MODE and UP button simultaneously This can be done while the controller is any mode or setting The calibration cycle ranges from 8 F to 8 F or 4 C to 4 C and will be applied to the probe sensor s measure ments HUMIDITY CALIBRATION To adjust the humidity that the probe sensor is measuring please press the MODE and DOWN bu...

Страница 20: ...RM ALERT This icon will flash when the high or low temperature alarm that you have set has been triggered HUMIDITY ALARM ALERT This icon will flash when the high or low humidity alarm that you have set has been triggered DISPLAY LOCK ALERT This icon is visible when the controller has been locked The icon will flash to alert you that the controller is locked if you try to change the mode or setting...

Страница 21: ...t fans designed to quietly ventilate AV rooms and closets as well as various DIY air circulation and exhaust projects Features a thermal controller with intelligent programming that will automatically adjust duct fan speeds in re sponse to changing temperatures Crawlspace Fans The AIRTITAN is a line of weather proof fans designed to provide ventilation odor and moisture control for crawl spaces an...

Страница 22: ...ively if the product becomes unusable The warranty program goes into effect on the date of purchase The program will expire two years from the date of purchase If your product becomes defective during that period AC Infinity will replace your product with a new one or issue you a full refund The warranty program does not cover abuse or misuse This includes physical damage submersion of the product...

Страница 23: ... part of the materials including graphics or logos available in this booklet may be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without specific permission from AC Infinity Inc ...

Страница 24: ...www acinfinity com ...