6.  Technical Specifications 

 

Parameters 

   Unit 

SHSG10000 

Dimensions (Ø x D) 

mm 

80 x 80 

Weight 

122 

Operating Temperature 

°C 

– 40 

Max. Humidity  

95 

IP Class 

 

20 

Radio frequency 

MHz 

868,42 (Z-Wave PLUS, Europe) 

Modulation 

 

FSK 

Material 

 

ABS 

Transmission power 

db 

< 4,5 

Power supply 

 

110 

– 240 V  AC 

Backup-Battery 

 

3.8 V / 700 mAh / Lithium 

Power consumption standby 

mA 

15 

Power consumption alarm 

mA 

19 

Battery-life 

 

4 hours or 5 minutes in case of emergency

 

Alarm volume 

dB 

95 @ 1m 

Range (open field) 

100 

Range (building) 

20, related to material of walls 

Tamper protection 

 

No 

Firmware updateable 

 

No 

Support Z-Wave Beaming 

 

No 

SmartStart unterstützt 

 

No 

Z-Wave Network Security 

 

Yes 

Z-Wave AES-128 Security 

 

Yes 

Z-Wave Plus 

 

Yes 

Security S2 Classes 

 

Yes 

Z-Wave Chip Generation 

 

500 

 

 

Содержание SHSG10000

Страница 1: ...0000 ABUS Z Wave Siren Important information and FAQs about this product and other products can be found on the website www abus com Version 1 0 Original operating instructions in English Keep for fut...

Страница 2: ...ormation on battery disposal 5 2 7 Cleaning 5 2 8 Information on device disposal 5 2 9 Power Supply 6 3 Product introduction 6 3 1 Scope of delivery 6 3 2 Device features 6 3 3 Operating Principle 7 3...

Страница 3: ...found at www abus com product SHSG10000 It can also be obtained at the following adress ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing GERMANY 1 2 Disclaimer of Liability These operat...

Страница 4: ...gnetic fields e g loudspeakers no naked flames e g lit candles are placed on or next to the device sprayed or dripping water is prevented from coming into contact with interior devices and caustic flu...

Страница 5: ...the restrictions set by the EU Directive 2006 66 EG If batteries are not disposed of properly these substances can cause harm to human health or the environment 2 7 Cleaning Dusty devices must be cle...

Страница 6: ...e or installation work The device is only fully disconnected from the mains network when the device is removed In order to eliminate the risk of fire the device s mains plug should always be disconnec...

Страница 7: ...nutes or operate in standby mode for approx 4 hours even when removed from the power supply 3 4 Performance features The ABUS Z Wave SHSG10000 is an radio siren with integrated backup battery is Z Wav...

Страница 8: ...on 3 times within 1 5 seconds and the Status LED will flash 3 times If the Add device process is successful the Status LED will turn off Repeat the inclusion process from step B if it was not successf...

Страница 9: ...d only be used if the primary gateway is not capable of acting 2 If the multi sensor is set to the factory setting the status is set to not included the association settings and possible configuration...

Страница 10: ...nd usually a BASIC SET is sent to all devices stored in an association group The siren supports the following association group Group Number Maximum Devices Transmitted Content Group 1 0x05 Associatio...

Страница 11: ...240 V AC Backup Battery 3 8 V 700 mAh Lithium Power consumption standby mA 15 Power consumption alarm mA 19 Battery life 4 hours or 5 minutes in case of emergency Alarm volume dB 95 1m Range open fie...

Отзывы: