2.5. Wake-up
If included:
The device sends a wake up notification command to
the node devices which are connected by a wake up
command.
The LED will light up when information is received, and
will go out when there is no exchange for 10 seconds.
If not included:
nothing
3. Advanced Z-Wave Parameter
3.1. Association Group Information
Z-Wave devices can control other devices directly. This direct control is called in Z-Wave association.
For this purpose, the device ID of the device to be controlled must be stored in the controlling devices.
This is done in so-called association groups. An association group is always linked to an event in the
controlling device (pressing a key or triggering a sensor). When this event occurs, a control command
- usually a BASIC SET - is sent to all devices stored in an association group
.
The sensor supports the following association group:
Group
Number
Maximum
Devices
Transmitted Content
Group 1
5
(0x05)
Z-Wave Plus Lifeline Notification Report
Sensor will send Notification Report when Motion Detection
Unknown Location and (Event inactive).
Multilevel Sensor Report
Sensor will send Multilevel Sensor Report (Temperature,
humidity, luminance) interval of 2 hours.
Battery Report.
Sensor will send Battery Report when the battery level is low
and the battery report’s value is 255 (0xFF).
Device Reset Locally.
Group 2
5
(0x05)
Send Basic Set when PIR trigger