Abus SHBW10000 Скачать руководство пользователя страница 4

 

English 

 

Information on handling batteries 

 

Make sure that batteries are kept away from small children. Children may put batteries in their 
mouths and swallow them. This can cause serious harm to their health. If this happens, consult 
a doctor immediately.

 

 

Do not charge normal batteries, heat them up or throw them into naked flames (they may 
explode). 

 

The battery must not be directly exposed to heat or sunlight, and must not be stored in a place 
with a very high temperature. 

 

The battery must not come into contact with water. 

 

The battery must not be dismantled, pierced or otherwise damaged. 

 

The battery contacts must not be short-circuited. 

 

Change low batteries in good time. 

 

Always change all the batteries at the same time and use batteries of the same type. 

 

Leaky or damaged batteries can cause chemical burns on contact with the skin. In this case, 
wear protective gloves. Clean the battery compartment with a dry cloth. 

 

Important information on battery disposal 

Batteries with this label do not contain harmful substances such as cadmium, lead and 
mercury. However, used batteries must not be disposed of along with household waste 
in accordance with the battery directive. To protect natural resources and promote the 
recycling of materials, separate the batteries from other waste and deposit them at a 
local recycling center. An additional label with the chemical symbols for Hg, Cd or Pb 
means that the batteries contain quantities of mercury, cadmium or lead which exceed 
the restrictions set by the EU Directive 2006/66/EG. If batteries are not disposed of 

properly, these substances can cause harm to human health or the environment 

 

Cleaning 

 

Dusty devices must be cleaned. You can clean dust from the air vents using a vacuum cleaner 
or compressed air. If necessary, you can remove the dust with a brush. 

 

You can clean the surface using a cloth slightly dampened in soapy water. Only use suitable 
microfiber cloths for high-gloss surfaces. 

 

Do not allow water to penetrate the device. 

 

Do not clean the device in a dishwasher. 

 

Do not use sharp, pointed, abrasive or corrosive cleaning materials or hard brushes. 

 

Do not use chemicals. 

 

Do not use flammable liquids for cleaning the device.  

 

Information on device disposal 

Important: The EU Directive 2012/19/EU regulates the proper return, treatment and 
recycling of used electronic devices. This symbol means that in the interest of 
environmental protection the device must be disposed of separately from household or 
industrial waste at the end of its service life in accordance with applicable local legal 
guidelines. Disposing of used devices can be done at official recycling centers in your 
country. Obey local regulations when disposing of material. Further details on returns 
(also for non-European countries) can be obtained at your local authority. Separate 

collection and recycling saves natural resources and ensures that all the provisions for protecting health 
and environment are observed when recycling the product. 

 

 

Содержание SHBW10000

Страница 1: ...ABUS Z Wave 4in1 Sensor Important information and FAQs about this product and other products can be found on the website www abus com Version 1 3 Original operating instructions in English Keep for f...

Страница 2: ...It can also be obtained at the following adress ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing GERMANY All contained company names and product designations are trademarks of the respe...

Страница 3: ...ust Please refer to the individual devices technical data for more detailed information Ensure that adequate ventilation is always guaranteed no direct sources of heat can affect the device interior d...

Страница 4: ...r Pb means that the batteries contain quantities of mercury cadmium or lead which exceed the restrictions set by the EU Directive 2006 66 EG If batteries are not disposed of properly these substances...

Страница 5: ...se in systems of different manufacturers 7 2 Overview of functions 8 2 1 Inclusion Add Device 8 2 2 Mounting Installation 9 2 3 Exclusion Remove Device 10 2 4 Reset Factory Reset 10 2 5 Wake up 11 3 A...

Страница 6: ...all mounting 1 3 Operating principle The SHBW10000 was developed for use in home automation systems that use the Z Wave wireless standard The multisensor has the following sensors PIR temperature atmo...

Страница 7: ...idity has a recognition range of max 5 meters has a battery empty warning function was developed for indoor installation 1 5 Use in systems of different manufacturers Communication is via the Z Wave E...

Страница 8: ...k the Add button in your Z Wave App and follow the further instructions Press the Button on the device once The App will show if the Add device process was successful The Status LED will light up for...

Страница 9: ...rom the battery compartment Fix the Mounting plate on the wall by screws recommended or adhesive tape Screw the detector onto the mounting plate and ensure that the two holes on the housing point down...

Страница 10: ...was not successful 2 4 Reset Factory Reset Keep pressing the Button on the device for more than 5 seconds the flash interval of the Status LED is now accelerated The device is now restored to factory...

Страница 11: ...An association group is always linked to an event in the controlling device pressing a key or triggering a sensor When this event occurs a control command usually a BASIC SET is sent to all devices s...

Страница 12: ...0 Waiting time from one PIR trigger to the next trigger Adjustable from 5 15300 in seconds Hexadecimal 0x05 0x3BC4 14 1 BASIC SET Command after PIR triggering 0 BASIC SET should be sent after triggeri...

Страница 13: ...value 0 disables the report Adjustable from 0 2678400 in seconds The value is always rounded up to the full minute e g 62 seconds value is rounded up to 120 seconds Hexadecimal 0x00 0x28DE80 110 1 Ena...

Страница 14: ...n for the time based report If the threshold value was not exceeded the time based report is not sent Adjustable from 1 100 in percent Hexadecimal 0x01 0x64 3 3 Command Classes Supported 1 Association...

Страница 15: ...50 PIR Trigger 24 times wakeup per day Range open field m 100 Range building m 20 related to material of walls Temperature Measuring range C 0 40 Humidity Measuring range 0 90 Light sensor Measuring...