29
o
PIN code error
o
GSM login error
o
GPRS IP address not received
o
Signal strength too low; login failed
ETH IP; the locally monitored Ethernet consists of:
o
Physical connection with LAN disrupted
o
Ethernet error (MAC address, ARP)
o
IP address not received
Monitoring, system notification enabled; the following
options are available in the menu:
o
Not active: system notification disabled
o
Active: system notification enabled
Delay, interval in hours, minutes and seconds: if the system
notification resets back to normal state within the set delay
time, no notification is issued.
Sequence: notifications are processed as per the sequence
set in the 'Transmission' tab. Note: a failed Ethernet
connection cannot be reported via an Ethernet connection.
Alarm, fixed error coding:
o
TA0001 Tamper alarm active
o
YS0009 GSM IP fail
o
YS0013 Ethernet IP fail
Reset, reset notification with fixed coding:
o
TR0001 Tamper alarm restore
o
YK0009 GSM IP OK
o
YK0013 Ethernet IP OK
Area: notification partition.
Text: free text field with 16 characters. This text is sent
when the inputs go into 'Alarm' and 'Reset' states. Use only
characters A to Z, 0 to 9 and do not use bookmarks or
international characters.
System setting:
o
Bypass area: the AZWG10200-PSTN/IP CONVERTER
provides the option of blocking notifications from this
area.
Outputs
The AZWG10200-PSTN/IP CONVERTER is equipped with two relay outputs.