12
4650-60 Issue 01
3. Delete button. You can delete any point at the end of the scan before
save. This button is only available when the scan is over.
4. Move selected points along the scan profile.
5. Stop the scan. The scan will stop after it has completed the current
section
6. End scan allows you to collect all the data at any time during the scan
and finish it.
7. Single point. This function allows to you add single points at the end of
the scan before you save it. This button is only available when the scan is
over.
8. Save the data into a file. This button is only available when the scan is
over.
If the scan stops suddenly and it is not over, please click on
End scan button and then save the scan.
You can also see in this screen the following information about the scan:
1. Current SE and Gauge in mm
2. Coordinates X & Y of each point of the scan from the left hand rail (LHR)
3. Graphical indication of the SE
4. Real position of the rails according to current gauge.
5. Centre of the track according to nominal gauge.
6. Relative or absolute mode. Relative mode does not take in account the
current SE during the scan, all the points are relative to the rails. Absolute
mode generates the points taking in to account the SE relative to the
ground.