Absolute Process Instruments Cecomp F20B Скачать руководство пользователя страница 1

Sensor Ranges and Engineering Units  

‡ -HA option not available

3 psig 

Res 15 psig vac 

Res

30 psia

Res

–15V100psig 

Res

300 psig

Res

3PSIG

.001

100KPAVAC

.1

2KGCMA

.001

–15V100PSIG

.1

300PSIG

.1

6INHGG

.001

0.1MPAVAC

.0001

2ATMA

.001

–30INHG/100PSIG

.1

610INHGG

.1

85INH2OG

.1

1BARVAC

.001

30 psig

Res

–30V200INHGG

.1

4800ZING

1

50ZING

.01

1KGCMVAC

.001

30PSIG

.01

–400V2770INH2OG

1

700FTH2O

.1

210GCMG

.1

1ATMVAC

.001

60INHGG

.01

–240V1600ZING

1

2000KPAG

1

150MMHGG

.1

15 psig

Res

850INH2OG

1

–760V5200MMHGG

1

2MPAG

.001

150TORRG

.1

15PSIG

.01

480ZING

.1

–760V5200TORRG

1

20BARG

.01

200MBARG

.1

30INHGG

.01

2100GCMG

1

–100V700KPAG

1

20KGCMG

.01

200CMH2OG

.1

400INH2OG

.1

1600MMHGG

1

–0.1V0.7MPAG

.001

20ATMG

.01

2000MMH2OG

1

240ZING

.1

1600TORRG

1

–1V7BARG

.01

500 psig

Res

7FTH2O

.001

1000GCMG 

1

2000MBARG

1

–1V7KGCMG

.01

500PSIG

.1

20KPAG

.01

760MMHGG

.1

2100CMH2OG

1

–1V7ATMG

.01

1020INHGG

1

5 psig 

Res

760TORRG

.1

70FTH2O

.01

100 psig

Res

1150FTH2O

1

5PSIG

.001

1000MBARG

1

200KPAG

.1

100PSIG

.1

3500KPAG

1

10INHGG

.01

1000CMH2OG

1

0.2MPAG

.0001

200INHGG

.1

3.5MPAG

.001

140INH2OG

.1

35FTH2O

.01

2BARG

.001

2770INH2OG

1

35BARG

.01

80ZING

.1

100KPAG

.1

2KGCMG

.001

1600ZING

1

35KGCMG

.01

350GCMG

.1

0.1MPAG

.0001

2ATMG

.001

7000GCMG

1

35ATMG

.01

260MMHGG

.1

1BARG

.001

60 psig

Res

5200MMHGG

1

1000 psig

Res

260TORRG

.1

1KGCMG

.001

60PSIG

.01

5200TORRG

1

1000PSIG

1

350MBARG

.1

1ATMG

.001

120INHGG

.1

7000MBARG

1

2040INHGG

1

350CMH2OG

.1

±15 psig 

Res

1660INH2OG

1

7000CMH2OG

1

2300FTH2O

1

3500MMH2OG

1

±15PSIG

.01

960ZING

1

230FTH2O

.1

7000KPAG

1

12FTH2O

.01

–30INHG/15PSIG

.01

4200GCMG

1

700KPAG

.1

7MPAG

.0001

35KPAG

.01

±30INHGG

.01

3100MMHGG

1

0.7MPAG

.0001

70BARG

.01

15 psia

Res

±400INH2OG

1

3100TORRG

1

7BARG

.001

70KGCMG

.01

15PSIA

.01

±240ZING

.1

4100MBARG

1

7KGCMG

.001

70ATMG

.01

30INHGA

.01

±1000GCMG

1

4200CMH2OG

1

7ATMG

.001

2000 psig

Res

400INH2OA

.1

±760MMHGG

1

140FTH2O

.1

–15V200 psig 

Res

2000PSIG

1

240ZINA

.1

±760TORRG

1

400KPAG

.1

–15V200PSIG

.1

4070INHGG

1

1000GCMA

1

±1000MBARG

1

0.4MPAG

.0001

–30INHG/200PSIG

.1

4600FTH2O

1

760MMHGA

.1

±1000CMH2OG

1

4BARG

.001

–30V400INHGG

.1

14MPAG

.01

760TORRA

.1

±100KPAG

.1

4KGCMG

.001

–400V5500INH2OG

1

140BARG

.1

1000MBARA

1

±0.1MPAG

.0001

4ATMG

.001

–240V3200ZING

1

140KGCMG

.1

1000CMH2OA

1

±1BARG

.001

100 psia

Res

–100V1400KPAG

1

140ATMG

.1

100KPAA

.1

±1KGCMG

.001

100PSIA

.1

–0.1V1.4MPAG

.001

3000 psig

Res

0.1MPAA

.0001

±1ATMG

.001

200INHGA

.1

–1V14BARG

.01

3000PSIG

1

1BARA

.001

30 psia

Res

2770INH2OA

1

–1V14KGCMG

.01

6100INHGG

1

1KGCMA

.001

30PSIA

.01

1600ZINA

1

–1V 14ATMG

.01

6900FTH2O

1

1ATMA

.001

60INHGA

.01

7000GCMA

1

200 psig

Res

20MPAG

.01

15 psig vac 

Res

850INH2OA

1

5200MMHGA

1

200PSIG

.1

200BARG

.1

15PSIVAC

.01

480ZINA

.1

5200TORRA

1

400INHGG

.1

200KGCMG

.1

30INHGVAC

.01

2100GCMA

1

7000MBARA

1

5500INH2OG

1

200ATMG

.1

400INH2OVAC

.1

1600MMHGA

1

7000CMH2OA

1

3200ZING

1

5000 psig

Res

240ZINVAC

.1

1600TORRA

1

700KPAA

.1

480FTH2O

.1

5000PSIG

1

1000GCMVAC

1

2000MBARA

1

0.7MPAA

.0001

1400KPAG

1

35MPAG

.01

760MMHGVAC

.1

2100CMH2OA

1

7BARA

.001

1.4MPAG

.001

350BARG

.1

760TORRVAC

.1

200KPAA

.1

7KGCMA

.001

14BARG

.01

350KGCMG

.1

1000MBARVAC

1

0.2MPAA

.0001

7ATMA

.001

14KGCMG

.01

340ATMG

.1

1000CMH2OVAC

1

2BARA

.001

14ATMG

.01

Cecomp

®

 Battery Powered Digital Pressure Gauges w. Memory Options & Selectable Units 

F20B, F22B

Ranges and Resolution

See table below for standard ranges and units 

Resolution is fixed for each engineering unit

Accuracy

Accuracy includes linearity, hysteresis, repeatability 

Standard accuracy:  ±0.25% of full scale ±1 least significant digit 

HA

 accuracy option: ±0.1% FS ±1 LSD, see ranges for availability 

Sensor hysteresis:  ±0.015% FS, included in accuracy 

Sensor repeatability: ±0.01% FS, included in accuracy

Display

3 readings per second nominal display update rate 

4 digit LCD, 0.5" H and 5 character 0.25" H alphanumeric 

BL models: red LED backlight

Batteries, Battery Life

B:  

2 AA alkaline, approx. 2000 hours 

BL:   2 AA alkaline, approx. 150 to 1500 hours depending on 

 

backlight usage

Controls and Functions

Three button keypad: Zero/clear, on/off, memory

BL models: Backlight active for 1 minute (user configurable)

F20B Peak Reading Memory

-M4:  MEM 1 ~ MEM 4 or 4 tire designations: LF, RF, LR, RR
-M8:  MEM 1 ~ MEM 8 or 4 tires plus 4 inner liner designations:  

 

LF, LF IN, RF, RF IN, LR, LR IN, RR, RR IN

F22B Min/Max Memory

Minimum and/or maximum readings stored in memory, readings 

cleared or stored at shutoff. User configurable.

Auto Shutoff

User selectable 1 minute to 8 hours or front button on/off 

Factory default 5 minutes, unless other time is specified

 

O

±0.25% Test Gauge Accuracy, ±0.1% Optional

 

O

316L Stainless Steel Wetted Parts

 

O

Keypad Selectable Units and Auto Shutoff Times

 

O

Store Readings in Memory

F20B, F22B

F20BN, F22BN 

NEMA 4X

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

Made in USA

Calibration

Zero button for gauge reference ranges 

Pass code protected calibration via keypad 

Non-interactive zero, span, and linearity, ±10% of range

Weight

Gauge: 

9 ounces (approximately)

Shipping: 

1 pound (approximately)

Materials

Standard: Extruded aluminum case, epoxy powder coated, ABS/ 

polycarbonate bezel, front and rear gaskets, polycarbonate label. 

NEMA 4X: UV stabilized ABS/polycarbonate case, polycarbonate dis-

play window, polycarbonate front label, rear gasket,  six stainless steel 

cover screws. Not intended for permanent outdoor installations.

Connection and Material

1/4" NPT male fitting

All wetted parts are 316L stainless steel

Overpressure, Burst, Vacuum Service

3000 psig sensor:  5000 psig overpressure 

5000 psig sensor:  7500 psig overpressure 

All others: 

2 X pressure range overpressure

Burst pressure:  

4 X sensor pressure rating, or 10,000 psi,  

 

whichever is less

Vacuum service: 

15 psia, 15 psig, ±15 psig, 30 psia, 100 psia, 

 

100 psig, 200 psig

Environmental Temperatures

Storage temperature: 

–40 to 203°F (–40 to 95°C) 

Operating temperature: 

–4 to 185°F (–20 to 85°C) 

Sensor compensated range: 

32 to 158°F (0 to 70°C)

Dimensions

See next page

How to Specify

Housing Backlit Memory

F20B

 range - 

M4

 - options

Standard

no

4 max  

reading

F20BBL

 range - 

M4

 - options

Yes

F20BN

 range - 

M4

 - options

NEMA 4X

no

F20BNBL

 range - 

M4

 - options

Yes

F20B

 range - 

M8

 - options

Standard

no

8 max  

reading

F20BBL

 range - 

M8

 - options

Yes

F20BN

 range - 

M8

 - options

NEMA 4X

no

F20BNBL

 range - 

M8

 - options

Yes

F22B

 range - options

Standard

no

Min/max

F22BBL

 range - options

Yes

F22BN

 range - options

NEMA 4X

no

F22BNBL

 range - options

Yes

Quick Link 

cecomp.com/bat

gauge reference pressure 

VAC  gauge reference vacuum 

absolute reference

 

psi = PSI 

  inHg = INHG 

 oz/in

2

 = ZIN 

 inH

2

O = INH2O 

 ftH

2

O = FTH2O 

  mmHg = MMHG 

 

torr = TORR 

 mmH

2

O = MMH2O 

 kg/cm

2

 = KGCM 

 g/cm

2

 = GCM 

 

kPa = KPA 

  MPa = MPA 

  mbar = MBAR 

 

bar = BAR 

 cmH

2

O = CMH2O 

 

atm = ATM

15V = –14.7 psi vac

30V = – 30 inHg vac

Range

—See table at left. Select a range code for default units. 

Options

—add to end of model number. See price list for details.

HA

High accuracy, ±0.1% FS ±1 LSD. See range table.

PM

Panel mount, 4.1" x 4.1", n/a NEMA 4X

FP

Sealed housing, CC for high-humidity food processing 

applications. NEMA models in absolute reference only.

MC

Metal front cover instead of plastic, n/a NEMA 4X

CS

Case bottom stiffener plate, n/a NEMA 4X

CC

Moisture resistant circuit board conformal coating

TP

Top port, gauge port on top of case, n/a NEMA 4X

SM

Surface mount plate, n/a NEMA 4X

CD

Calibration data, 5 test points and date 

NC

NIST traceability documentation, 5 points and date

Accessories

—order separately

CON14SS

Quick connector to install or remove gauge with-

out tools. 304 stainless steel, urethane seal.

SCR14SS

Filter screen fitting keeps debris out of gauge 

sensor. For food vacuum packaging applications. 

303SS body, 100 micron 304SS screen. 

RB

High visibility orange rubber boot protects gauge 

for portable applications. Not available with NEMA 

4X models.

TP

Top gauge port. Primarily used with tire pressure 

applications. Not available with NEMA 4X models.

© 02-21

cecomp.com

1220 American Way Libertyville, IL 60048 

800-942-0315

CECOMP

 

Div. of

 

A

A

BSOLUTE

BSOLUTE

 P

 P

ROCESS

ROCESS

 I

 I

NSTRUMENTS

NSTRUMENTS

Содержание Cecomp F20B

Страница 1: ... usage Controls and Functions Three button keypad Zero clear on off memory BL models Backlight active for 1 minute user configurable F20B Peak Reading Memory M4 MEM 1 MEM 4 or 4 tire designations LF RF LR RR M8 MEM 1 MEM 8 or 4 tires plus 4 inner liner designations LF LF IN RF RF IN LR LR IN RR RR IN F22B Min Max Memory Minimum and or maximum readings stored in memory readings cleared or stored at...

Страница 2: ...y be easier before installation Contact the factory for assistance 4 These products do not contain user serviceable parts except batteries Contact us for repairs service or refurbishment 4 Gauges must be operated within specified ambient temperature ranges 4 Permanent installations must be indoors only Outdoor or wash down applications require installation in a NEMA 4X housing 4 Use a pressure or ...

Страница 3: ...e maximum stored value The center power button may be pressed at any time to return to the normal display mode The gauge may be left in the maximum dis play mode if desired The maximum reading will be continuously displayed stored and updated Press and release the Memory button to view the minimum stored value For many applications it may be best to bring the system up to normal pressure and then ...

Страница 4: ...all buttons when the display indicates CFG Calibration Pass Code With the unit off press and hold the t button to view and or change the user calibration pass code Then press the Power but ton Release all buttons when the display indicates CAL Change Pass Code Mode Before the unit enters the view or change pass code mode the display initially indicates _ _ _ _ with the first underscore blinking an...

Отзывы: