background image

DC to DC Transmitters, High Voltage Input, Isolated, Field Rangeable 

API 4380 G HV3

Input:

 

0-1 V to ±200 VDC

Wide Ranging I/O

Output:

 

0-1 V to ±10 VDC or 0-2 mA to 4-20 mA

One Minute Setup!

 

O

One Minute Field Setup for Hundreds of I/O Ranges

 

O

External Switches & Tables for Range Selection

 

O

Full 2000 V Input/Output/Power Isolation

 

O

Input and Output LoopTracker

®

 LEDs

 

O

Output Test Button

 

O

Built-In Loop Power Supply for Output

 

Q

Convert, Boost, Rescale Process Signals

 

Q

One Model Covers Multiple Applications

 

Q

Interface Process Signals with Panel Meters, PLCs, 
Recorders, Data Acquisition, DCS, and SCADA 
Systems

Applications

Description 

The API 4380 G HV3 accepts a DC voltage input and provides 
an optically isolated DC voltage or current output that is linearly 
related to the input. This module is unique because it is field 
rangeable for voltage inputs to ±200 VDC. Typical applications 
include signal isolation and signal conversion. 
The optical isolation between input and output makes this 
module useful for ground loop elimination, common mode 
signal rejection, and noise pickup reduction. The module 
power supply is isolated, resulting in full 3-way (input, output, 
power) isolation.
The API 4380 G HV3 input and output can be field-configured 
via external rotary and slide switches. Common range settings 
are on the module label. Most common ranges are built-in, and 
can be selected from the table on the module, however virtually 
unlimited combinations are possible. Consult the factory for 
assistance with special ranges.

LoopTracker 

API exclusive features include two LoopTracker LEDs (green for 
input, red for output) that vary in intensity with changes in the 
process input and output signals. These provide a quick visual 
picture of your process loop at all times and can greatly aid in 
saving time during initial startup and/or troubleshooting. 

Output Test 

An API exclusive feature includes the Functional Test Button 
to provide a fixed output (independent of the input) when held 
depressed. The test output level can be set via a potentiometer 
from 0 to 100% of the output span. 
The functional test button greatly aids in saving time during 
initial startup and/or troubleshooting.

Installation

The API 4380 G HV3 plug into an industry standard 8-pin octal 
socket sold separately. Sockets API 008 and finger-safe API 
008 FS allow either DIN rail or panel mounting.
The plug-in design, 3-way isolation, and robust electronics 
allows the module to be quickly hot-swapped without removing 
the power or I/O signals.

DC Input Ranges

See table on other side for field selectable ranges 
Consult factory for special ranges 
System voltages must not exceed socket voltage rating
Voltage: 

0-1 VDC 

to 

0-200 VDC 

Bipolar voltage: 

±1 VDC 

to 

±200 VDC

Input Impedance

Voltage:  1 M

W

 minimum

Common Mode Rejection

120 dB minimum

LoopTracker

Variable brightness LEDs indicate I/O loop level and status

DC Output Ranges

See table on other side for field selectable ranges 
Consult factory for special ranges
Voltage, 10 mA max.:  0-1 VDC  to 

0-10 VDC

Bipolar voltage: 

±1 VDC  to 

±10 VDC

Current: 

0-2 mADC  to  0-20 mADC
20 V compliance, 1000 

W

 at 20 mA

Output Calibration

Multi-turn zero and span potentiometers for output 
±15% of span adjustment range typical

Output Loop Power Supply

20 VDC nominal, regulated, 25 mADC, max. ripple <10 mV

RMS

Output Test

Sets output to test level when pressed 
Adjustable 0-100% of span 
Potentiometer factory set to approx. 50% of span

Output Ripple and Noise

Less than 10 mV

RMS

Linearity

Better than ±0.1% of span

Ambient Temperature Range and Stability

–10°C to +60°C operating ambient 

Better than ±0.02% of span per °C stability

Response Time

100 milliseconds typical 
DF option: 30 milliseconds typical response time

Isolation

2000 V

RMS

 minimum 

Full isolation: power to input, power to output, input to output

Installation Environment

IP 40, requires installation in panel or enclosure 
Use with API 008 or API 008 FS socket 
Socket mounts to 35 mm DIN rail or can be surface mounted 
UL 508C pollution degree 2 environments or better

Power

Standard: 

115 VAC ±10%, 50/60 Hz, 2.5 W max. 

P option: 

85-265 VAC 50/60 Hz, 60-300 VDC, 2.5 W 

A230 option:  230 VAC ±10%, 50/60 Hz, 2.5 W max. 
D option: 

9-30 VDC, 2.5 W typical

Hot Swappable 

Plug-In Design

Sourcing 

mA Output

Sink or 

Source  

mA Input

Free Factory Setup 

Specify I/O ranges if factory is to set switches 

Options—add to end of model number
DF

  30 millisecond response time, or consult factory 

DF option will cause output noise levels greater than  
standard specifications. 

U

 

Conformal coating for moisture resistance

Accessories—order as separate line item
API 008

 

8-pin socket

API 008 FS

  8-pin finger-safe socket 

API CLP1

  Module hold-down spring for high vibration or  

mobile applications

Model

Input

Output

Power

API 4380 G HV3

Field configurable 

Specify input range if factory is 

to set switches

Field configurable 

Specify output range if factory is 

to set switches

115 VAC

API 4380 G HV3 A230

230 VAC

API 4380 G HV3 P

85-265 VAC or 60-300 VDC

API 4380 G HV3 D

9-30 VDC

2.75"

Free Factory 

I/O Setup!

2.38"

1.75"

Variable Brightness 

Input LED

Output Test Button

Output Test Adjust

Output Span

Output Zero
Variable Brightness 

Output LED

 H H H H H H

  H H H H H

H H H H H H

  H H H H H

 H H H H H H

  H H H H H

H H H H H H

  H H H H H

 H H H H H H

Made in USA

Minute 

Setup!

1

API 008 

600 V Rating

API 008 FS 

300 V Rating

API CLP1

Quick Link 

api-usa.com/hvdc

E145968

115 VAC, 230 VAC models 

with input up to ±150 VDC

www.mod-tronic.com | [email protected] | 1-800-794-5883