Input:

 

0-100 mV to 300 VDC, 0-1 mA to 0-5 ADC, 4-20 mADC

Output:

  One 8 Amp DPDT Relay or Two 8 Amp SPDT Relays

 

O

Field Adjustable Setpoints

 

O

Plug-In Design for Fast Installation

 

O

Input LoopTracker

®

 and Alarm Status LEDs

 

O

Alarm Test, Optional Reset Button

 

O

Sinking mA Input

 

Q

Process Limit Backup Alarm

 

Q

Tank Level Alarm

 

Q

Process Signal Over, Under, Out-of-Range Alarm

Model

Input

Standard Alarm Configuration

Power

API 1000 G

Factory ranged, specify 

mV, V, or mA range 

Order 

5A

 shunt option for 0-900 

mADC to 0-5 ADC inputs

Single setpoint one DPDT relay 

HI alarm, non-latching, normal acting

115 VAC

API 1000 G A230

230 VAC

API 1000 G P

85-265 VAC or 60-300 VDC

API 1000 G D

9-30 VDC

API 1020 G

Factory ranged, specify 

mV, V, or mA range 

Order 

5A

 shunt option for 0-900 

mADC to 0-5 ADC inputs

2 setpoints, 2 SPDT relays  

HI/LO alarms, non-latching, normal acting

115 VAC

API 1020 G A230

230 VAC

API 1020 G P

85-265 VAC or 60-300 VDC

API 1020 G D

9-30 VDC

DC Input Range

Factory configured, please specify input type and range 
System voltages should not exceed socket voltage rating
Voltage: 

0-100 mVDC  to  0-300 VDC 

Current: 

0-1 mADC 

to  0-900 mADC sinking 

5A

 option: 

0-900 mADC  to  0-5 ADC

Input Impedance and Burden

Voltage: 

250 k

 minimum 

Current: 50 

 typical 

Voltage burden:  1.25 VDC at 20 mA current input

Isolation and Input Protection

750 VAC

p

 or 750 VDC common mode protection 

Input isolated from power supply

LoopTracker

Variable brightness LED indicates input loop level and status

API 1000 G Relay Output

Two SPDT form C contact sets operating in unison as one 
DPDT contact set 
One setpoint, 12 turn potentiometer, 0-100% of span 
Factory configured alarm type 
Standard:  HI alarm, non-latching, normal acting 
Options:  LO alarm, latching, reverse acting

API 1020 G Relay Output

Two independent SPDT form C contact sets 
Two setpoints, two 12 turn potentiometers, 0-100% of span 
Factory configured alarm action 
Internal jumpers for HI/LO, LO/LO, HI/HI, LO/HI 
Standard:  HI/LO alarm, non-latching, normal acting 
Options:  LO/LO, HI/HI, LO/HI alarms, latching, reverse acting

Relay Contact Rating

8 A @ 240 VAC resistive load or 30 VDC resistive load 
5 A @ 240 VAC inductive load (cos 

= 0.4) 

3.5 A @ 30 VDC inductive load (L/R = 7ms)
See graph on other side for relay load ratings
Caution:  Do not exceed socket voltage rating 
 

Use an RC snubber for inductive loads

Deadband

Alarm trip/reset window is symmetrical about the setpoint 

API 1000 G

  1.0 to 100% of span, 12 turn potentiometer. 

API 1020 G

  Fixed at 1% of span, standard 

API 1020 G A

  Adjustable deadbands, 1.0 to 100% of span,  

 

1 turn potentiometer for each setpoint

Output Test/Reset Button

Toggles relay(s) to opposite state when pressed 
Resets latching relay with 

HT

 option, available on 1000 G only

Response Time

70 milliseconds typical

Ambient Temperature Range and Stability

–10°C to +60°C operating ambient 
Better than 0.02% of span per °C stability

Housing and Sockets

IP 40, requires installation in panel or enclosure 
API 011 or API 011 FS socket
Socket mounts to 35 mm DIN rail or can be surface mounted

Power

Standard: 

115 VAC ±10%, 50/60 Hz, 2.5 W max. 

P option: 

85-265 VAC 50/60 Hz, 60-300 VDC, 2.5 W typ. 

A230 option:  230 VAC ±10%, 50/60 Hz, 2.5 W max. 
D option: 

9-30 VDC, 2.5 W typical

Options—add to end of model number
L

 

1000 G with LO trip. Alarm trips on decreasing signal.

HT

  1000 G latching alarm with push button reset

HP

  1000 G latching alarm with power-off reset. 

 

Module power must be turned off to reset alarms

HH

  1020 G with HI/HI trip. Alarms trip at their respective  

 

trip points on increasing signal.

LL

  1020 G with LO/LO trip. Alarms trip at their respective  

 

trip points on decreasing signal.

A

 

1020 G with adjustable deadbands.

R

 

Reverse-acting alarms. Relay coils energized in an alarm 

 

condition. No alarm condition with module power off.

5A

   Shunt for 0-900 mADC to 0-5 ADC inputs. Includes  

 

API 011 socket and 0.1 

 25W 1% shunt resistor.

U

 

Conformal coating for moisture resistance

Accessories—order as a separate line item
API 011

 

11-pin socket, DIN rail or surface mount 

API 011 FS

 11-pin finger safe socket, DIN rail or surface mount 

API CLP1

  Module hold-down spring for high vibration or  

 

mobile applications

DC Input Alarm Trips, Factory Ranged 

API 1000 G, API 1020 G

Applications

Description

The API 1000 G and API 1020 G are factory configured for 
either a DC voltage or current input and provide alarm contact 
outputs. Heavy duty relay contacts allow the module to directly 
control high capacity loads.
The API 1000 G provides a single setpoint adjustment and 
DPDT relay contacts. The alarm output can be factory config-
ured for HI or LO operation, non-latching or latching, normal 
or reverse acting. Top-accessible potentiometers are used to 
adjust the alarm setpoint and deadband.
The API 1020 G contains two independent setpoints with two 
SPDT relay contact outputs. The alarm output can be factory 
configured for HI/HI, HI/LO, LO/HI or LO/LO operation, normal 
acting or reverse acting. Top-accessible potentiometers are 
used to adjust each alarm setpoint. Deadband is fixed at 1% of 
span. Adjustable deadbands are optional.

LoopTracker and Alarm Status LEDs

API exclusive features include a LoopTracker LED that varies in 
intensity with changes in the process input signal.
A red/green bi-color alarm status LED (two on the API 1020 
G) visually indicate alarm status. These LEDs provide a quick 
visual picture of your process at all times. 

Output Test/Unlatch

API’s exclusive functional test button can be used to verify the 
alarm and system operation. The output test button greatly 
aids in saving time during initial startup and/or troubleshooting. 
The HT latching option provides the additional function of 
unlatching the alarm when the reset button is pressed. The 
alarm will reset if the alarm condition not longer exists.

API 1020 G

P 001 001

115 VAC

Your Required Input

Your Alarm Configuration

2.75"

Free Factory 

I/O Setup!

Quick Link 

api-usa.com/1000

API 1000 G

Variable Brightness Input LED

Bi-Color Relay LED

Deadband Adjustment
Setpoint Adjustment

Output Test Button 
Reset w. HT Option

2.38"

1.75"

API 1020 G

A

 Option Deadband Adjustments

2.38"

1.75"

Variable Brightness Input LED
Bi-Color Relay 2 LED
Bi-Color Relay 1 LED

Setpoint 2 Adjustment
Setpoint 1 Adjustment

Output Test Button

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

Made in USA

Hot Swappable 

Plug-In Design

API 011 

300 V Rating

API 011 FS 

300 V Rating

API CLP1

© 08-18

api-usa.com

1220 American Way Libertyville, IL 60048 
Phone: 

800-942-0315

 

Fax: 800-949-7502

A

BSOLUTE

 P

ROCESS

 I

NSTRUMENTS