High Voltage DC to DC Transmitters, Isolated, Field Rangeable 

APD HV-DC

Input:

 

0-100 VDC to 0-1200 VDC

Output:

 

0-1 V to ±10 VDC or 0-2 mA to 4-20 mA

 

O

Field Selectable I/O Ranges

 

O

Zero and Span Output Calibration Potentiometers

 

O

Full 1200 V Input/Output/Power Isolation

 

O

Input and Output LoopTracker

®

 LEDs

 

O

Output Test Button

 

O

Selectable Sink/Source for Current Output

Applications

Options–add to end of model number
C

 

Custom range, >1200 VDC to 2000 VDC max.

U

 

Conformal coating for moisture resistance

Accessory—order as separate line item
API PB4

 

Spare removable plug, black 4 terminal

Model

Input

Output

Power

APD HV-DC

8 field selectable ranges 

1 custom input range can be  

specified if required

18 field selectable ranges

85-265 VAC or 60-300 VDC

APD HV-DC D

9-30 VDC or 10-32 VAC

Function 

The APD HV-DC accepts a DC voltage input and provides an 
optically isolated DC voltage or current output that is linearly 
related to the input. This module is unique because it is field 
rangeable for voltage inputs from 100 VDC to 1200 VDC. 
Typical applications include signal isolation and signal conver-
sion for a high voltage DC input.

Isolation 

The optical isolation between input and output makes this 
module useful for ground loop elimination, common mode 
signal rejection or noise pickup reduction. The module power 
supply is isolated, resulting in full 3-way (input, output, power) 
isolation.

Fast Field Setup

The APD HV-DC input and output range settings can be recon-
figured in the field via external switches. Range settings are 
on the module label. A user specified range is available that 
can be factory configured to meet your specific requirements. 
Consult the factory for assistance.

Sink/Source Output

For maximum versatility the output can be selectively wired for 
sinking or sourcing. The built-in 20 VDC loop excitation supply 
may be used to power passive mA devices. This allows the APD 
HV-DC to work with powered or unpowered mA devices.

LoopTracker

API exclusive features include two LoopTracker LEDs (green for 
input, red for output) that vary in intensity with changes in the 
process input and output signals. These provide a quick visual 
picture of your process loop at all times and can greatly aid in 
saving time during initial startup and/or troubleshooting. 

Output Test 

An API exclusive feature includes a test button to provide a 
fixed output (independent of the input) when held depressed. 
The test output level is potentiometer adjustable from 0 to 
100% of output span. 
The output test button greatly aids in saving time during initial 
startup and/or troubleshooting.

All models are field rangeable

Free factory setup and calibration
The APD HV-DC has a custom input range than can be factory 
set to your specifications at no extra cost

How to Order

Please specify

Model 
Input range (if you would like us to set the switches) 
Output range (if you would like us to set the switches) 
Custom range, if required 
Option as required

Input Ranges

8 field selectable ranges 
 

0-100 VDC 

 

0-200 VDC 

 

0-300 VDC 

 

0-400 VDC 

 

0-500 VDC 

 

0-1000 VDC 

 

0-1200 VDC 

 

Custom range—consult factory, 2000 VDC max.

Input Impedance (Voltage)

2.5 M

Common Mode Rejection

120 dB minimum

LoopTracker

Variable brightness LEDs indicate I/O loop level and status

Output Ranges

18 field selectable ranges
Voltage: 

0-1 V, 0-2 V, 0-4 V, 0-5 V, 1-5 V, 0-8 V,  

 

0-10 V, 2-10 V

Bipolar voltage:  ±5 V, ±10 V
Current: 

0-2 mA, 0-4 mA, 0-8 mA, 0-10 mA,  

 

2-10 mA, 0-16 mA, 0-20 mA, 4-20 mA 

 

20 V compliance, 1000 

 at 20 mA 

Consult factory for special ranges

Output Calibration

Multi-turn zero and span potentiometers to compensate for 
load and lead variations 
±15% of span adjustment range typical

Output Loop Power Supply

20 VDC nominal, regulated, 25 mADC, max. ripple <10 mV

RMS

May be selectively wired for sinking or sourcing mA output

Output Test

Front button sets output to test level when pressed 
Potentiometer adjustable 0-100% of span

Output Ripple and Noise

Less than 10 mV

RMS

 ripple and noise

Linearity

Better than ±0.1% of span

Ambient Temperature Range and Stability

–10°C to +60°C operating ambient 

Better than ±0.04% of span per °C stability

Response Time

100 milliseconds nominal

Isolation

1200 V

RMS

 minimum 

Full isolation: power to input, power to output, input to output

Power

85-265 VAC, 50/60 Hz or 60-300 VDC, 2 W maximum 
D versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximum

Housing and Connectors

IP 40, requires installation in panel or enclosure 
Mount vertically to a 35 mm DIN rail 
Four 4-terminal removable connectors, 14 AWG max wire size

Dimensions

0.89" W x 4.62" H x 4.81" D   
22.5 mm W x 117 mm H x 122 mm D  
Height includes connectors

Universal 

Power

Removable Plugs

Sink or Source  

mA Output

Output LoopTracker 

LED

Input LoopTracker 

LED

Zero and Span for 

Output

Custom I/O Ranges

Adjustable Output 

Test/Override 

Function

High Voltage 

DC Input

 

Q

High Voltage Battery Systems 

 

Q

DC Motor and Variable Speed Drives

 

Q

Electric Railway Voltages

 

Q

Power Supply and Voltage Converters

1  2  3  4

5  6  7  8

9 10 11 12

13 14 15 16

See Wiring 

Diagrams on 

Next Page

© 07-20

api-usa.com

1220 American Way Libertyville, IL 60048 
Phone: 

800-942-0315

 

Fax: 800-949-7502

A

A

BSOLUTE

BSOLUTE

 P

 P

ROCESS

ROCESS

 I

 I

NSTRUMENTS

NSTRUMENTS

Quick Link: 

api-usa.com/HVDC

Minute 

Setup!

1

Free Factory 

I/O Setup!

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

Made in USA

Applications Link 

api-usa.com/apps

Pb

Lead 

Free

Отзывы: