Absolute Process Instruments APD 44H Series Скачать руководство пользователя страница 1

High/Low Select Transmitters, 2 to 4 DC Inputs to 1 DC Output, Factory Configured  APD 44Hx, APD 44Lx

© 11-19

Input:

 

0-50 mV to 0-10 VDC, ±25mV to ±10VDC, 0-1 mA to 0-20 mADC, ±0.5 to ±20 mA

Output:

 

0-1 V to ±10 VDC or 0-2 mA to 0-20 mA, 4-20 mA

 

O

Versions to Follow the Highest or the Lowest Input

 

O

1200 V Input/Output/Power Isolation

 

O

Input LoopTracker

®

 LED

 

O

Zero and Span Output Calibration Potentiometers

 

O

Functional Test Button

 

O

Built-In Loop Power Supply for Output

 

Q

Track Highest or Lowest of Multiple Input Signals

 

Q

Monitor Maximum Flow From Multiple Pumps

 

Q

Sensor Redundancy

Applications

Options—add to end of model number
M01

 

Input/output reversal, such as 4-20 mA input to  

 

20-4 mA output 

U

 

Conformal coating for moisture resistance

Accessory—order as separate line item
API BP4

  Spare 4-terminal plug, black

Model

Inputs: Factory Configured Output: Factory Configured

Power

APD 44H2

High select from 2 inputs 

Specify 2 input ranges

Specify VDC or mADC range

85-265 VAC or 60-300 VDC

APD 44H2 D

9-30 VDC or 10-32 VAC

APD 44H3

High select from 3 inputs 

Specify 3 input ranges

Specify VDC or mADC range

85-265 VAC or 60-300 VDC

APD 44H3 D

9-30 VDC or 10-32 VAC

APD 44H4

High select from 4 inputs 

Specify 4 input ranges

Specify VDC or mADC range

85-265 VAC or 60-300 VDC

APD 44H4 D

9-30 VDC or 10-32 VAC

APD 44L2

Low select from 2 inputs 

Specify 2 input ranges

Specify VDC or mADC range

85-265 VAC or 60-300 VDC

APD 44L2 D

9-30 VDC or 10-32 VAC

APD 44L3

Low select from 3 inputs 

Specify 3 input ranges

Specify VDC or mADC range

85-265 VAC or 60-300 VDC

APD 44L3 D

9-30 VDC or 10-32 VAC

APD 44L4

Low select from 4 inputs 

Specify 4 input ranges

Specify VDC or mADC range

85-265 VAC or 60-300 VDC

APD 44L4 D

9-30 VDC or 10-32 VAC

All models are factory ranged 

The APD 44Lx or APD 44Hx series is configured to your 
specifications
Each input can have different ranges and/or units

How to Order

With the model number, please specify 

2, 3, or 4 input ranges depending on the model 
Output range 
Options as required

Description 

The APD 44xx series accepts 2, 3 or, 4 DC voltage or current 
inputs, depending on the model. They provide an optically 
isolated DC voltage or current output that is linearly related to 
the highest or lowest of the inputs, depending on the model. 
They are used where the highest or lowest of multiple inputs 
are required to drive the output, or where sensor redundancy 
is needed. Full 3-way isolation (input, output, power) makes 
this module useful for ground loop elimination, common mode 
signal rejection or noise pickup reduction. The inputs are not 
isolated from each other. 
The APD 44xx series can be wired to allow a mA output to be 
either sinking (passive) or sourcing (active). 

LoopTracker 

API exclusive features include a green LoopTracker LED that 
varies in intensity with changes in the process input signal. It 
provides a quick indication of your process input at all times 
and can greatly aid in saving time during initial startup and/or 
troubleshooting.

Functional Test 

An API exclusive feature includes the Functional Test Button to 
provide a fixed output (independent of the input) when enabled. 
The test output level is potentiometer adjustable from 0 to 100% 
of output span. The functional test button greatly aids in saving 
time during initial startup and/or troubleshooting.

DC Input Range

Factory configured, please specify each input range or con-
sult factory for special ranges. Each input can have different 
ranges and/or units. mA inputs are sinking.
Voltage: 

0-50 mVDC  to 

0-10 VDC 

Bipolar voltage: 

±25 mVDC  to 

±10 VDC 

Current: 

0-1 mADC  to  0-20 mADC 

Bipolar current: 

±0.5 mADC  to  ±20 mADC

Input Impedance

Voltage: 

50 k

 minimum 

Current: 50 

 nominal

Balance Between Inputs

Better than ±0.5% of span

LoopTracker

Variable brightness LED indicates input loop level and status

DC Output Range

Factory configured, please specify output range
Voltage, 10 mA max.:  0-1 VDC  to 

0-10 VDC 

Bipolar voltage: 

±1 VDC  to 

±10 VDC 

Current: 

0-2 mADC  to  0-20 mADC

 

20 V compliance, 1000 

 at 20 mA 

Milliamp output can be field wired for sink or source.

Output Calibration

Multi-turn zero and span potentiometers 
±15% of output span typical

Output Loop Power Supply

20 VDC nominal, regulated, 25 mADC, <10 mV

RMS

 

max. ripple

May be selectively wired for sinking or sourcing mA output

Output Test

Front button sets output to test level. Enabled via pushbutton.
Default setting approximately 50% of span 
Potentiometer adjustable 0-100% of span

Output Ripple and Noise

Less than ±0.2% of span

Linearity

Better than ±0.25% of span

Ambient Temperature Range and Stability

–10°C to +60°C operating ambient 

Better than ±0.02% of span per °C stability

Response Time

50 milliseconds, nominal per channel used

Isolation

1200 V

RMS

 minimum 

Full isolation: power to each input, power to output, each 
input to output. 
Non-isolated: input to input

Housing and Connectors

IP 40, requires installation in panel or enclosure 
For use in Pollution Degree 2 Environment 
Mount vertically to a 35 mm DIN rail 
Four 4-terminal removable connectors, 14 AWG max wire size

Power

85-265 VAC, 50/60HZ or 60-300 VDC, 4W maximum 
D versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 4 W maximum

Dimensions

0.89" W x 4.62" H x 4.81" D   
22.5 mm W x 117 mm H x 122 mm D  
Height includes connectors

api-usa.com

1220 American Way Libertyville, IL 60048 
Phone: 

800-942-0315

 

Fax: 800-949-7502

A

A

BSOLUTE

BSOLUTE

 P

 P

ROCESS

ROCESS

 I

 I

NSTRUMENTS

NSTRUMENTS

Removable Plugs

Sink or Source mA Output

Input LoopTracker 

LED

Zero and Span for 

Output

Custom I/O Ranges

Adjustable Output 

Test/Override 

Function

Mixed Voltage or mA Inputs

Universal Power

1  2  3  4

5  6  7  8

9 10 11 12

13 14 15 16

See Wiring 

Diagrams on 

Next Page

Quick Link: 

api-usa.com/math

Free Factory 

I/O Setup!

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

Made in USA

File E145968

85-265 VAC, 60-300 VDC 

model only

Pb

Lead 

Free