background image

 

 

 
 
 

 

 ABSOLUTE OZONE 

OZONE GENERATOR 

Models ATLAS/TITAN/MAGNUM 25-200 

 

 

OPERATOR’S MANUAL

 

 

 

Absolute Ozone 

10712 - 181 Street, Edmonton, Alberta, T5S 1K8, Canada 

780-486-3761 

 

Содержание ATLAS Series

Страница 1: ...ABSOLUTE OZONE OZONE GENERATOR Models ATLAS TITAN MAGNUM 25 200 OPERATOR S MANUAL Absolute Ozone 10712 181 Street Edmonton Alberta T5S 1K8 Canada 780 486 3761...

Страница 2: ...ECTION 4 Maintenance and Service 11 4A Preventative Maintenance 11 4B Troubleshooting 11 SECTION 5 Replacement Parts 13 SECTION 6 Ozone Overview and Safety Procedures 13 6A Ozone Use and Technology Ov...

Страница 3: ...ical Ozone Injection System Diagram 21 SECTION 1 General Information IMPORTANT SAFETY INSTRUCTIONS PLEASE READ AND FOLLOW ALL INSTRUCTIONS Read this manual completely before operation of ATLAS TITAN M...

Страница 4: ...one Output as specified in supplied performance chart g h Gas Flow Rate min 0 05 SLPM Gas Flow Rate max as specified in supplied performance chart SLPM By Weight 03 5 12 6 14 for ATLAS TITAN 25 100C M...

Страница 5: ...vent Ozone Generator flooding Please note Non return valves check valves do not provide 100 protection to ozone generator We do not recommend installing ozone generator without this device Ozone Injec...

Страница 6: ...ical power and required gas connections and cooling air to the Ozone Generator Do not obstruct cooling air vents of the Generator Unit could be installed indoors outdoors if protected from weather ele...

Страница 7: ...ate for ozone and oxygen applications Connect the Ozone Generator according to indications on input and output bulkheads All efforts should be made to protect the generator from exposure to excessive...

Страница 8: ...ol terminals to enabling operator ambient ozone monitor or PLC to remotely switch the Ozone Generator On or Off This contacts have to be connected to dry contact only not connected to the ground on an...

Страница 9: ...normally open for the generator to be On and closed to stop the Ozone production That switch has to be connected to dry contacts only not connected to the ground on any kind or to any voltage source...

Страница 10: ...trol SECTION 3 Operation 3A Control Panel Overview 1 Green LED Power On 2 Red LED Safety Shutoff Remote Control Off 3 Power On Off Switch 4 Ozone Production Adjustment Dial 1A 120 240VAC 24VDC Remote...

Страница 11: ...or Performance Test chart Now the generator is in optimum production mode and ozone should be flowing though the system 3C System Shutdown 1 Turn the potentiometer fully counterclockwise 2 Turn the Oz...

Страница 12: ...oltage and install power conditioning devices if necessary SECTION 4 Maintenance and Service 4A Preventative Maintenance Generally the ATLAS TITAN MAGNUM 25 200 are maintenance free although it is use...

Страница 13: ...it out by running oxygen though the generator without power that could take from a few hours to several days Do not power the generator unless absolutely sure that it is dry Running the generator with...

Страница 14: ...g compares the strengths of several common oxidizing reagents EOP vs Cl2 Elemental Fluorine 2 25 Hydroxyl Radical 2 05 Ozone 1 52 Hydrogen Peroxide 1 30 Hypochlorite 1 10 Chlorine 1 00 Chlorine Dioxid...

Страница 15: ...eous ozone to which workers may be exposed is 0 1 ppm averaged over 8 hours 5 days a week OSHA The short term exposure limit is 0 3 ppm averaged over 15 minutes The concentration of 5 0 ppm ozone in a...

Страница 16: ...lations Do not bury the electrical cord To reduce risk of electrical shock replace damaged cord immediately 6C 4 Fire Hazards Ozone is nonflammable Decomposition of ozone into oxygen gas O2 can increa...

Страница 17: ...e atmosphere Personnel should leave the affected area until levels are returned to below 0 1ppm 6D 4 Respiratory Protection A disposable respirator 3M N95 8214 8514 Minneapolis MN www 3m com is recomm...

Страница 18: ...urer s instructions The planned maintenance of all safety equipment is essential to worker safety 6E 2 Maintenance Requirements It is the joint responsibility of the manufacturer supplier and installe...

Страница 19: ...reathing has been restored 5 Send for medical assistance immediately 6 If absent begin cardiopulmonary resuscitation CPR 6G 3 Eye Contact 1 Effective irrigation should start immediately Eyes should be...

Страница 20: ...e defective in materials or workmanship within Five 5 years from data of original purchase Parts are covered under the Five 5 year warranty when and only when required operating conditions and procedu...

Страница 21: ...PARTICULAR PURPOSE AND SUCH WARRANTIES ARE HEREBY DISCLAIMED AND g ABSOLUTE OZONE SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR LOSS OF USE OF SUCH PRODUCTS LOST PROFITS DIRECT DAMAGES INDIRECT DAM...

Страница 22: ...ller Mechanical Contractor 3 Serial and date of purchase 4 The date of failure 5 A description of the failure 6 All shipping documents should clearly state Warranty Repair and indicated RMA number Abs...

Страница 23: ...ensions and mounting hole dimensions Dimensions 14 x 26 5 x 7 Mounting holes dimensions W12 x H27 7 8 7 ATLAS 25 100 Ozone Generator dimensions and mounting hole dimensions Dimensions 14 x 15 x 7 Moun...

Страница 24: ...23 Comment All System Components and Materials have to be Ozone Compatible 8 Typical Ozone Injection System Diagrams for Water Treatment...

Страница 25: ...24 Comment All System Components and Materials have to be Ozone Compatible 9 Notes...

Отзывы: