Transducer Instruction Manual 

Range:   

LETIX 

Type: 

 

L-ANV-0-0-R-AC 

Revision:   

V1.0 

2.

 

Installation

 

2.1 

Mechanical 

 

The installation of this unit 

MUST

 be carried out by a competent person who has the relevant knowledge 

and ability to install the unit in a safe manner, The installation is not the responsibility of CMC Controls or 
Absolute Measurement Ltd. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The Indicator must be installed in a dry, non-hazardous location. A panel cut out of 92 mm (+1.0/0.0 mm) 
x 45 mm  (+1.0/0.0 mm) is required. The depth of the Indicator is 125 mm but extra provision must be 
allowed for cable connections. A single fixing clip, behind the unit, retains the Indicator. To install, simply 
insert the Indicator into the cut out and fit the clip to hold the Indicator in place. 
 
The tension transducers must be installed in accordance with the installation procedure from the 
transducer handbook.  See the transducer part of the handbook or a specific drawing for the connection 
details and wire colours. 

2.2 

Unit Electrical Connection Diagram 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1

2

3

4

5

6

7

8

9

10

11

12 13

19

14 15

16 17 18

   ANALOG
O/P OPTION

-

+

SERIAL DATA
 O/P OPTION

SIGNAL I/P & EXCITATION

LOGIC INPUTS

POWER

SEN-

SIG-

EXC-

SIG+

SEN+ EXC+

ALA

RM 

LOCK

CALI

B'n 

LO

CK

N

L

-

+

LETIX Connection Diagram

 Not
Used

Содержание L-ANV-0-0-R-AC

Страница 1: ...Amplifier Instruction Manual Range LETIX Type L ANV 0 0 R AC Supply 110 240V AC Output 0 10V Revision V1 0...

Страница 2: ...s 1 1 General Description 2 2 Installation 3 2 1 Mechanical 3 2 2 Unit Electrical Connection Diagram 3 2 3 Transducer Electrical Connection Diagrams 4 2 4 Supply Connection Diagram 6 3 Supply Voltage...

Страница 3: ...n in the web The electrical signal from the transducers is a combination of tension force and sensing roller deadweight The effect of the weight of the sensing roller is removed electrically leaving t...

Страница 4: ...icator must be installed in a dry non hazardous location A panel cut out of 92 mm 1 0 0 0 mm x 45 mm 1 0 0 0 mm is required The depth of the Indicator is 125 mm but extra provision must be allowed for...

Страница 5: ...ucer Electrical Connection Diagrams Connections for a Cleveland Kidder Classic Semi Conductor Transducer one Half Bridge Transducer Connections for two Cleveland Kidder Classic Semi Conductor Transduc...

Страница 6: ...Instruction Manual Range LETIX Type L ANV 0 0 R AC Revision V1 0 Connections for one Cleveland Ultra Semi Conductor Transducer or one Full Bridge Foil Gauge Transducer 1 2 3 4 5 6 Red Green Blue WIRIN...

Страница 7: ...C Controls t 0 1732 763278 e sales absolutemeasurement co uk w absolutemeasurement co uk Unit 19 Silver Birches Business Park Aston Road Bromsgrove B60 3EU 6 Transducer Instruction Manual Range LETIX...

Страница 8: ...e AC Mains and the screens of the transducers and any other cable should be bonded to earth locally with short leads 4 Calibration 4 1 Indicator This is usually pre set by CMC to the clients needs bef...

Страница 9: ...press OK again for display to read for example 0 0 The input calibration is now finished and the tension indicator should read correctly 4 6 Output Signal Calibration Once the tension calibration has...

Страница 10: ...eland Kidder Classic and Ultra series and 10v for foil type transducers In addition measure the differential millivolt signal at full transducer load to ensure that the unit is given signals within it...

Отзывы: