User Manual для Absen 3.0 C110 теперь доступен для скачивания бесплатно на нашем сайте. Подробное руководство поможет вам настроить и использовать продукт идеально. Скачайте его прямо сейчас с manualshive.com.
Absenicon3.0 Series C110
User Manual
Страница 1: ...Absenicon3 0 Series C110 User Manual ...
Страница 2: ...stallation 13 2 1 Installation guide 13 2 2 Installation method of moving 13 2 2 1 Install frame 13 2 2 2 Install support legs 14 2 2 3 Install cabinet 15 2 2 4 Install edging 17 2 2 5 Install module 18 2 3 Installation method of wall mounted 19 2 3 1 Assemble frame 19 2 3 2 Install frame fixed connecting plate 20 2 3 3 Fixed the frame 20 2 3 4 Install cabinet 21 2 2 5 Install edging 22 2 3 6 Inst...
Страница 3: ...e any questions please seek help from Absen Beware of Electric Shock To prevent electric shock the device must be properly grounded during installation Do not ignore using the grounding plug or else there is a risk of electric shock During a lightning storm please disconnect the device s power supply or provide other suitable lightning protection If the equipment is not in use for a long time plea...
Страница 4: ...ion around the display screen controller power supply and other devices and keep a minimum 0 1 meter gap with other objects Do not stick or hang anything on the screen Do not modify the product do not add or remove parts Do not use the product in case ambient temperature is over 55 Beware of Injury Warning Wear a helmet to avoid injury Ensure any structures used to support fix and connect the equi...
Страница 5: ... Please contact us directly for detailed environmental performance information WARNING Beware of suspended loads LED lamps used in the module are sensitive and can be damaged by ESD electrostatic discharge To prevent damage to LED lamps do not touch when the device is running or switched off WARNING The manufacturer shall not bear any responsibility for any incorrect inappropriate irresponsible or...
Страница 6: ...CC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential are...
Страница 7: ...e efficiency Absenicon3 0 series conference screens bring a brand new large screen visual experience for the conference room which can share the speaker s intelligent terminal content to the conference screen at any time without complicated cable connection and easily realize wireless projection of multi platform terminals of Windows Mac OS iOS and Android At the same time according to different c...
Страница 8: ...ue light mode for eye protection bring comfortable experience 5 Ultra high contrast ratio of 5000 1 110 NTSC large color space showing colorful colors and the smallest visible details are in front of you 6 160 ultra wide display viewing angle everyone is the protagonist 7 28 5mm ultra thin thickness 5mm ultra narrow frame 8 Built in audio dividable frequency processing treble and bass ultra wide a...
Страница 9: ...ates quickly and efficiently improve the welcome atmosphere 15 Support remote control can adjust brightness switch signal source adjust color temperature and other operations one hand can control various functions 16 All kinds of interfaces are available and peripheral devices can access 17 A variety of installation methods to meet your installation needs 2 people 2 hours rapid installation All mo...
Страница 10: ...r consumption w 1200 System Parameters Android system Android8 0 System configuration 1 7G 64 bit quad core processor Mail T820 GPU System memory DDR4 4GB Storage capacity 16GB eMMC5 1 control interface MiniUSB 1 RJ45 1 I O interface HDMI2 0 IN 3 USB2 0 1 USB3 0 3 Audio OUT 1 SPDIF OUT 1 RJ45 1 Automatic sharing of network and control OPS Optional Support Environmental Parameters Operating Tempera...
Страница 11: ...ckaging of the all in one machine is mainly composed of three parts box module packaging 1 4 modular packaging installation structure packaging movable bracket or wall hanging edging The cabinet packaging is unified to 2010 870 500mm Three 1 4 cabinets free packaging into honeycomb box overall size 2010 870 500mm ...
Страница 12: ...on3 0 C110 User Manual 12 one 1 4 cabinet and four 4 1 4 module packages and edge into the honeycomb box dimensions 2010 870 500mm Installation structure packaging figure take the movable bracket as an example ...
Страница 13: ...of installation number front view 2 2 Installation method of moving 2 2 1 Install frame Take out the frame from the packing box including the cross beam and vertical beam Place it on the ground Number description The first digit is the screen number the second digit is the cabinet number from top to bottom the top is the first row The third place is the cabinet column number For example 1 1 2 is t...
Страница 14: ...to choose for the height of the bottom of the screen surface from the ground 800mm 880mm and 960mm corresponding to different installation holes of the vertical beam The default position of the bottom of the screen is 800mm from the ground the height of the screen is 2177mm the highest position is 960mm and the height of the screen is 2337mm The side of the beam with screw holes is facing up The v...
Страница 15: ... the support leg and a total of 6 M8 screws on both sides are installed 2 2 3 Install cabinet Hang the middle row of cabinet first and hook connecting plate on the back of the cabinet into the notch of the cross beam of the frame Move the cabinet to the center and align the marking line on the beam ...
Страница 16: ...e is subject to the actual product 2 Hang the cabinets on the left and right sides in turn and lock the left and right connecting bolts on the cabinet The four corner hook connecting plate of the screen are flat connecting plate Note The internal structure is subject to the actual product Left and right connecting bolts ...
Страница 17: ...es of the bottom edging 16 M3 flat head screws 2 Fix the lower edging to the bottom row of cabinets tighten 6 M6 screws and connect the power and signal wires of the lower edging and the bottom cabinet Note The internal structure is subject to the actual product 3 Install the left right and top edging using M3 flat head screws Left and right connecting plate ...
Страница 18: ...Absenicon3 0 C110 User Manual 18 Note The internal structure is subject to the actual product 2 2 5 Install module Install the modules in order of number ...
Страница 19: ...ss beam and vertical beam Place it on the ground with the front facing upwards the side with the silk printed logo on the beam is the front Assemble the four sides of the frame including two beams two vertical beams and 8 M8 screws 横梁 The side of the beam with screw holes is facing up vertical beam The vertical beam has a gap on the side facing inward ...
Страница 20: ...ly 4 connecting plates on the four sides can be installed when the wall bearing capacity is good 2 3 3 Fixed the frame After the frame fixed connecting plate is installed install the frame fix it with 2 M6 16 screws at each position and clamp it up and down After the connecting plate is installed install the back frame and fix it with 2 M6 16 screws at each position the screws are topped into the ...
Страница 21: ...binet first and hook connecting plate on the back of the cabinet into the notch of the cross beam of the frame Move the cabinet to the center and align the marking line on the beam 2 Install 4 M4 safety screws after the cabinet is installed Flat connecting plate Hook connecting plate ...
Страница 22: ...inet The four corner hook connecting plate of the screen are flat connecting plate Note The internal structure is subject to the actual product 2 3 5 Install edging 1 Install the edging under the screen and tighten the fixing screws of the left and right connecting plates of the bottom edging 16 M3 flat head screws Cabinet M4 safety screws Hook connecting plate cross beam Left and right connecting...
Страница 23: ...abinets tighten 6 M6 screws and connect the power and signal wires of the lower edging and the bottom cabinet Note The internal structure is subject to the actual product 3 Install the left right and top edging using M3 flat head screws left and right connecting plates of edging ...
Страница 24: ...24 Note The internal structure is subject to the actual product 2 3 6 Install module Install the modules in order of number Please refer to Absenicon3 0 C138 user manual for system operation instructions and maintenance instructions ...