background image

Universal Voltage 40W, 60W, 80W permits operation at 

120VAC thru 277VAC or 347VAC or 480VAC, 50 or 60 Hz.

Add: 

1501 Industrial Way N, Toms River, NJ 08755   

Phone:

 866-222-8866   

E-mail: 

[email protected]

 

Web:

 www.AboveAllLighting.com ©2016 ABOVE ALL Lighting, Inc. All rights reserved

SMT LED AREA LIGHT

Instructions Manual

1

SUITABLE FOR MODEL

WIRE CONNECTION

Make the following Electrical Connection:

a). Connect the voltage supply line to ACL in Black.

b). Connect the voltage supply Neutral to ACN in White.

c). Connect Green ground lead to the supply ground lead.

SAFETY INSTRUCTION

READ CAREFULLY BEFORE INSTALLING FIXTURE. 

PLEASE KEEP THIS MANUAL FOR FUTURE USE.

Fixtures must be wired in accordance with the National 

Electrical Code and all applicable local codes. Proper 

grounding is required for safety.

THIS PRODUCT MUST BE INSTALLED IN 

ACCORDANCE WITH THE APPLICATION CODE BY 

A PERSON FAMILIAR WITH THE CONSTRUCTION 

AND OPERATION OF THE PRODUCT AND THE 

HAZARDS INVOLVED.

MAKE CERTAIN POWER IS OFF BEFORE 

INSTALLING OR MAINTAINING FIXTURE.

CHECK THAT VOLTAGE IS COMPATIBLE WITH 

FIXTURE DRIVER. USE APPROVED CONNECTORS 

FOR ALL ELECTRICAL CONNECTIONS.

MAINTENANCE CAUTION

1. Review the wire connection before beginning, and 

make sure fixture is grounded properly.

2. For lighting controls, follow control instructions 

carefully.

3.  Turn  power  off  and  wait  for  fixture  to  cool  before 

performing maintenance.

4. Maintenance must be done by professionals.

Note:

 If fxture is furnished with photocell receptacle, 

please make sure install the photocell or shorting cap

INSTALLATION

ACCESSORY PACK

WIRE NUT X 3

PHOTOCELL X 1

SHORTING CAP X 1

WIRE NUT X 3

WIRE NUT X 3

WIRE NUT X 3

 SCREW M6*18 X 4

 SPRING WASHER M6 X 4

GASKET X 1

GASKET X 2

SCREW M8*30 X 2

SCREW M8*30 X 2

+

ROUND POLE 

ADAPTER X 1

NUT M8 X 2

NUT M8 X 2

WARNING

Risk of injury or damage. Make certain 
power is OFF before installing or maintaining 
fixture.

ACCESSORY PACK FOR SF AND TR

ACCESSORY PACK FOR PHOTOCELL

ACCESSORY PACK FOR 7 PIN

ACCESSORY PACK FOR SAR

ACCESSORY PACK FOR RAR

ACCESSORY PACK FOR WM

ACCESSORY PACK SHIPPED SEPARATE WITH 

SKU#90204 

1

Содержание SMT Series

Страница 1: ...HE HAZARDS INVOLVED MAKE CERTAIN POWER IS OFF BEFORE INSTALLING OR MAINTAINING FIXTURE CHECK THAT VOLTAGE IS COMPATIBLE WITH FIXTURE DRIVER USE APPROVED CONNECTORS FOR ALL ELECTRICAL CONNECTIONS MAINTENANCE CAUTION 1 Review the wire connection before beginning and make sure fixture is grounded properly 2 For lighting controls follow control instructions carefully 3 Turn power off and wait for fixt...

Страница 2: ...rm Door Screws 7 Secure Pole Top Cap not supplied ROUND POLE ARM MOUNT RAR Drill the pole according to the drill pattern Fig 1 NUT 2 GASKET 2 WAHSHER 2 LOCKING WAHSHER 2 ARM DOOR BOLTS 2 ADAPTER BOLTS 2 ARM DOOR LOCKING WASHERS 2 WASHERS 2 WASHERS 2 NUT 2 GASKET 1 Loosen 2 Screws on the Arm Door and open the Door 2 Feed Supply Wires through the center opening of Pole not supplied 3 Insert one Bolt...

Страница 3: ...e can be used as guidelines to adjust the angle 4 Tighten the Locking Bolt and replace the Slipfitter Cover Plate with removed 2 screws SLIPFITTER MOUNT SF SCREWS 2 LOCKING BOLT SET SCREW 2 SLIPFITTER COVER PLATE 1 Install the trunnion to a desired bracketry by the center hole using 2 Bolts 2 Locking Washers and 2 Nuts not supplied according to the Drill Pattern 2 Adjust the angle of the fixture b...

Страница 4: ...e wires into the Embedded Junction Box Secure the Wall Mount Bracket to the wall with Screw M6 18 4 and Spring Washer M6 4 Notes Make sure the waterproof treatments are done well when making wiring and closing junction box Fig 3 EMBEDDED JUNCTION BOX CUSTOMER SUPPLIED SUPPORT WIRE HOLE SCREW M6 18 AND SPRING WASHER M6 4 WALL MOUNT BRACKET Ref 20109 11217 Note If fixture is furnished with photocell...

Отзывы: