Installation and power supply connection
9
Installation and power supply connection
The electrical installation of the
eMH1
charging station model variants described in this
manual must always be carried out by qualified specialist personnel: Please contact an
electrical contractor or arrange installation at your premises with your local distributor.
However, as a user you may carry out the mechanical installation of the charging sta-
tion yourself, as long as you follow the safety notices and general instructions.
Prerequisites for the mounting site and installation
Your
eMH1
charging station is an electrical device and is therefore subject to particular
prerequisites for indoor and outdoor installation: Although the housing of the
eMH1
complies with the standards for the IP54 degree of protection, you must take into ac-
count certain environmental conditions, especially outdoors.
In selecting the mounting site you must consider the following points:
• For the safe operation of your charging station, minimum distances to other tech-
nical installations must be observed: You can obtain further information from your
electrical contractor or your distributor.
• The charging station must be installed where it is freely accessible to all authorized
users.
• Ideally, the mounting site should already provide a connection to the power supply.
If not, a separate supply must be installed that complies with the generally pre-
scribed standards for cabling and building infrastructure: Please contact a qualified
electrical contractor for details.
WARNING!
The power supply for the
eMH1
must ALWAYS be protected by a do-
mestic miniature circuit breaker (MCB).
The supply cable has be protected by an additional external FI residual
current circuit breaker (RCCB). Further information available under
“Specifications”, see page 23.
• This charging station is designed for connection to and operation on a rated voltage
of 230/ 400 V 50 Hz.