Abilia GEWA Connect Скачать руководство пользователя страница 11

11 

 

Android 
Settings 

Opens Android Settings 

 

Cancel 

Closes the 

Longpress menu

 

 

 

5. 

GEWA Settings app 

Settings can be changed in the 

GEWA Settings

 application. A menu is shown for the 

available settings: 

  Scanning settings 

 

Point scanning speed 

The speed of the crosshair when it moves across the 
screen, first vertically then horizontally (1-20, default 5) 

 

Row scanning speed 

The time each object is selected when scanning through 
all objects on the screen (0.1-2 sec, default 1 sec) 

 

Initial scanning delay 

The delay before the scanning leaves the first item after 
pressing on the switch (0.0-10.0 sec, default 0.5 sec) 

 

Longpress menu 
delay 

The time you need to press the switch before the 

Longpress menu

 is shown (1.0-5.0 sec, default 2.5 sec) 

 

No Click menu if 
single action 

Hides the 

Click menu

 if the selected object has Tap 

functionality only (default: Enabled) 

 

  Phone settings 

Quick settings for scanning users, e.g. volume, brightness and timeout. 

 

Phone volume 

Media volume 

– the volume for music, etc. 

Alarm volume 

– the volume for alarm signals 

Notification volume 

– the volume for notifications from 

SMS, apps, etc. 
System volume 

– volume on or off (except alarm volume). 

Ringtone volume 

– the volume when the phone is ringing 

 

Auto Screen 
brightness 

Let the phone automatically adjust the screen's 
brightness based on ambient lighting 

 

Screen brightness 

Adjust the screen's brightness manually (0-8) 

 

Screen timeout 

Adjust the time before the screen switches off after 
inactivity 

 

Screen on while 
charging 

Prevent the screen going to timeout when the phone is 
charging 

 

 

 

Содержание GEWA Connect

Страница 1: ...Rev E EN Manual GEWA Connect Version 2 1 419881 Andromeda Socket UK 419882 Andromeda Socket FR 419883 Andromeda Socket CH 419884 Andromeda Socket DK Art no 461180...

Страница 2: ...2...

Страница 3: ...9 Discover the Alert function 9 4 Menus reached by the control switch 10 Click menu 10 Longpress menu 10 5 GEWA Settings app 11 Scanning settings 11 Phone settings 11 Multibox 12 Backup Restore 12 GEW...

Страница 4: ...tibox 21 8 Move GEWA Connect to another smartphone 22 If GEWA Connect should be used by the same user 22 If GEWA Connect should be used by another user 22 9 Safety and responsibility 22 10 Technical d...

Страница 5: ...ect 3 To secure that GEWA Connect is always active and working you should a make the recommended system settings on the smartphone see 3 2 Recommendations b keep the Multibox near the smartphone less...

Страница 6: ...Point scanning In cases where row scanning is insufficient you can switch to point scanning for more detailed navigation and to replicate mouse navigation and clicks taps This is useful for operating...

Страница 7: ...at the screen lock works with scanning If not don t use it Make sure that apps to be used can be used with scanning If an app is not scanning compatible try another one from Google Play Store Ensure t...

Страница 8: ...ount Then tap LOG IN 3 5 2 Add Multibox Choose Add Multibox and follow the instructions in the Wizard to connect the Multibox Wait for the Multibox to connect 3 5 3 Configure permissions Choose Setup...

Страница 9: ...again to close in on a more exact position 9 The Click menu is shown choose Tap to tap on the position 10 Wait for 10 seconds and the scanning will stop the crosshair disappears If you want to change...

Страница 10: ...switch for 2 5 seconds The delay time can be customised see chapter 5 1 Scanning settings The Longpress menu has the following features Swap Switches between Point scanning and Row scanning The icon d...

Страница 11: ...fore the Longpress menu is shown 1 0 5 0 sec default 2 5 sec No Click menu if single action Hides the Click menu if the selected object has Tap functionality only default Enabled Phone settings Quick...

Страница 12: ...e is complete Backup Restore From here you can make a backup of GEWA Connect s data e g the page sets for environmental control scanning settings etc Use the backup to restore GEWA Connect on the same...

Страница 13: ...the function 3 Select type and follow the instructions Notice that the symbol or means that it doesn t have an IR or GR command and therefore cannot be used for Alert yet Warning When using the Alert...

Страница 14: ...the name and or the symbol first The IR signal is recorded afterwards or selected from existing GEWA link or GEWA 4096 codes Then you can also choose if and how the signal should be repeated A button...

Страница 15: ...Start the GEWA Connect application 2 Go to the App menu and select Switch to Edit Mode 3 Tap on New 4 Tap on to select a symbol e g 5 Tap on Name Enter a name e g lamp 6 Tap on Type and select IR item...

Страница 16: ...available for testing 7 Tap on the button s menu and select Add IR command 8 Select Record IR and follow the instructions to record IR 9 Go to the App menu and select Switch to Normal mode 10 Test yo...

Страница 17: ...ro is a combination of existing IR items with optional delay between each IR item Follow these steps to get a quick tutorial on how to create your own button with Macro function for environmental cont...

Страница 18: ...e for the new page 8 Tap on to save 9 Now fill out the buttons on the new page with commands for environmental control used in the bedroom 10 Go to the App menu and select Switch to Normal mode The sh...

Страница 19: ...ose door Open door Close window Open window Close curtains Open curtain Wall socket 3 pin wall socket Wall switch Switch off Environmental control TV Digibox DVD VCR Stereo Music Portable radio Speake...

Страница 20: ...the micro USB port I on the Multibox Battery indicator The status of the battery is indicated on the battery symbol D No indication The Multibox is OFF Green light every 5 seconds The Multibox is ON a...

Страница 21: ...ies in the remote control Using relay output for Alert When using the Alert function it is possible to send an alert via the relay output Connect the relay function to to SW1 or SW2 the one not used f...

Страница 22: ...new users myAbilia account 9 Safety and responsibility Abilia has conducted a risk analysis for the product with reference to SS EN 14971 for Medical equipment The instructions for use and the techni...

Страница 23: ...t Used for charging and data transfer when updating Multibox Power supply 5 V Size H x W x D 108 x 67 x 22 mm Weight 153 g Conformance with the Medical Devices Directive GEWA Connect is marketed as a...

Страница 24: ...24 www abilia com Latest version of this document and manuals in other languages are available on our website 461180_Manual GEWA Connect_EN_RevE Sept 2018...

Отзывы: