4.2  Control with Radio transmitter 

4.2.1  Radio transmitter (Z-Wave) 
Example:

 To turn a lamp on and off every other time you press the button on the Z-wave      

      transmitter. 
When controlling with radio you can only have the On/Off function (bistable function). 
Andromeda Socket can be included and operated in any Z-Wave network with other  

Z-Wave certified devices from other manufacturers and/or other applications. All non-battery 

operated nodes within the network will act as repeaters regardless of vendor to increase reliability of 

the network. 

4.2.2  Z-Wave network functions 
Add (Include): 

1.  Put the system controller (Z-Wave transmitter) into inclusion mode (Include) by following the 

instructions provided by the controller manufacturer. 

2.  Press the 

On/Off

 button on Andromeda Socket three times within 1.5 seconds. 

Remove (Exclude): 

1.  Put the system controller (Z-Wave transmitter) into exclusion mode (Exclude) by following the 

instructions provided by the controller manufacturer. 

2.  Press the 

On/Off

 button on Andromeda Socket three times within 1.5 seconds. 

Reset (Reset): 

1.  Press and hold the 

On/Off

 button on Andromeda Socket for approx. 6 seconds until the 

indication light glows steadily. 

2.  Release the 

On/Off

 button on and press ones again within 3 seconds. 

NOTE:

 Use this procedure only in the event that the system controller (Z-Wave transmitter) is   

     missing or otherwise inoperable. 

Associating Andromeda Socket in a Z-Wave Network (Associate): 

The Andromeda Socket supports the Association Group 1 (Lifeline) and up to 5 devices can be 

added to this group. Association process only works after the device has been included to a Z-Wave 

network. 

1.  Put the controller into Association mode. Some controllers can automatically associate. See the 

controller manufacturer manual. 

2.  Identify Andromeda Socket to the controller by sending the node information, do this by 

pressing the 

On/Off

 button three times within 1.5 seconds. 

3.  The controller should confirm association when the process is successfully completed. See the 

controller manufacturer manual for more information. 

 

 

 

Содержание Gewa Andromeda 419881

Страница 1: ...Andromeda Socket User manual Art Nr 419881 EN UK 1 0...

Страница 2: ...smitter 6 4 3 Control with control switch 7 5 Resetting to default setting 8 6 Cleaning 8 7 Storage and disposal 8 7 1 Storage 8 7 2 Disposal 8 8 Technical data 9 8 1 Environment 9 8 2 Technical data...

Страница 3: ...nd therefore can be used together with all of these products including Gewa IR transmitter and Z Wave transmitter The Andromeda Socket comes factory set with GewaLink channel 16 and bistable function...

Страница 4: ...d ensure that the device is on for example a lamp should be lit 2 Connect the Andromeda Socket to a wall socket 3 Connect the device to be controlled to the socket on the relay unit 1 4 Make sure that...

Страница 5: ...button on the IR transmitter until the indication light on the relay unit flashes and the relay have clicked 3 times 2 Check the function by pressing the selected button on the IR transmitter 4 1 2 K...

Страница 6: ...ons provided by the controller manufacturer 2 Press the On Off button on Andromeda Socket three times within 1 5 seconds Reset Reset 1 Press and hold the On Off button on Andromeda Socket for approx 6...

Страница 7: ...ndication light on the relay unit flashes and the relay have clicked 3 times 3 Check the function by pressing the control switch 4 3 2 Keep turned on monostable function Example To practice cause and...

Страница 8: ...tion Z Wave network functions for more info 6 Cleaning The Andromeda Socket can be cleaned with a damp cotton wool pad with surgical spirit Chlorhexidine ethyl alcohol or isopropanol It can also be cl...

Страница 9: ...ower consumption 2 0 W Maximum relay load 2990 VA 13 A resistive load Programming channels GewaLink channels 0 127 channel 62 has no function and 4096 code Frequency Z Wave 868 42 MHz Input control sw...

Страница 10: ...ed or might lead to either of these situations The death of a patient user or other person The temporary or permanent serious deterioration of a patient s user s or other person s state of health A se...

Страница 11: ...se Norway Abilia AS Tevlingveien 23 1081 Oslo Norway Phone 47 23 28 94 00 support abilia no www abilia no United Kingdom Abilia UK Ltd Unit12 Buckingway Business Park Swavesey Cambridge CB24 4AE Unit...

Страница 12: ...12 Abilia AB R sundav gen 6 Solna Sweden Phone 46 0 8 594 694 00 info abilia uk www abilia uk 419880 81_User manual_Andromeda Socket_EN UK_March 2021...

Отзывы: