9. Important information 

Before you use the product, read and understand the contents of this user manual. 

9.1  Safety 

Safety definitions 

 WARNING:

 Risk of injury or death if the instructions are not followed. 

 CAUTION:

 Risk of damage to the product if the instructions are not followed. 

NOTE:

 Information that is necessary in a given situation.

  

9.2  Safety instructions for operation 

 

 WARNING:

 Read the following warning instructions before you use the product. 

 

  For safety reasons, never connect devices that requires continuous power supply, e.g., life 

support devices. 

  For safety reasons, never connect devices in series! 

  The relay is activated during the programming. This may cause an inadvertent activation of 

some equipment. 

9.3  Serious incidents 

If a serious incident related to the product occurs, this must be reported to the manufacturer and the 

competent authority of your country. 

 

An incident is regarded serious if it directly or indirectly led, might have led or might lead to either of 

these situations: 

  The death of a patient, user or other person. 

  The temporary or permanent serious deterioration of a patient's, user's or other person's 

state of health. 

  A serious public health threat. 

9.4  Conformance with requirements for medical devices 

Andromeda Socket is marketed as a technical aid for people with disabilities. It complies with all 

necessary requirements, regulations and directives for medical devices. 

9.5   Product liability 

The product has been developed and risk-assessed in accordance with ISO 14971. The user 

manual and the technical specifications are made according to the safety assessments in the risk 

analysis. Always consider the safety when using the product. If the product is used in other ways 

than the intended use, it may involve risks for which Abilia AB does not take responsibility. The 

estimated life of the product applies when used in accordance with its intended use and 

maintenance instructions. 
Abilia AB is not liable for any loss, damage or consequential loss if the product has been used or 

installed in any way other than as specified in this document. Any form of damage or tamp. 
 

 

Содержание Gewa Andromeda 419881

Страница 1: ...Andromeda Socket User manual Art Nr 419881 EN UK 1 0...

Страница 2: ...smitter 6 4 3 Control with control switch 7 5 Resetting to default setting 8 6 Cleaning 8 7 Storage and disposal 8 7 1 Storage 8 7 2 Disposal 8 8 Technical data 9 8 1 Environment 9 8 2 Technical data...

Страница 3: ...nd therefore can be used together with all of these products including Gewa IR transmitter and Z Wave transmitter The Andromeda Socket comes factory set with GewaLink channel 16 and bistable function...

Страница 4: ...d ensure that the device is on for example a lamp should be lit 2 Connect the Andromeda Socket to a wall socket 3 Connect the device to be controlled to the socket on the relay unit 1 4 Make sure that...

Страница 5: ...button on the IR transmitter until the indication light on the relay unit flashes and the relay have clicked 3 times 2 Check the function by pressing the selected button on the IR transmitter 4 1 2 K...

Страница 6: ...ons provided by the controller manufacturer 2 Press the On Off button on Andromeda Socket three times within 1 5 seconds Reset Reset 1 Press and hold the On Off button on Andromeda Socket for approx 6...

Страница 7: ...ndication light on the relay unit flashes and the relay have clicked 3 times 3 Check the function by pressing the control switch 4 3 2 Keep turned on monostable function Example To practice cause and...

Страница 8: ...tion Z Wave network functions for more info 6 Cleaning The Andromeda Socket can be cleaned with a damp cotton wool pad with surgical spirit Chlorhexidine ethyl alcohol or isopropanol It can also be cl...

Страница 9: ...ower consumption 2 0 W Maximum relay load 2990 VA 13 A resistive load Programming channels GewaLink channels 0 127 channel 62 has no function and 4096 code Frequency Z Wave 868 42 MHz Input control sw...

Страница 10: ...ed or might lead to either of these situations The death of a patient user or other person The temporary or permanent serious deterioration of a patient s user s or other person s state of health A se...

Страница 11: ...se Norway Abilia AS Tevlingveien 23 1081 Oslo Norway Phone 47 23 28 94 00 support abilia no www abilia no United Kingdom Abilia UK Ltd Unit12 Buckingway Business Park Swavesey Cambridge CB24 4AE Unit...

Страница 12: ...12 Abilia AB R sundav gen 6 Solna Sweden Phone 46 0 8 594 694 00 info abilia uk www abilia uk 419880 81_User manual_Andromeda Socket_EN UK_March 2021...

Отзывы: