xFUME VAC ADVANCED
6 Putting into operation
BAL.0731.0 • 2019-09-18
EN - 13
6.4 Establishing an electrical connection
For the mains voltage and the fuse protection, please refer to:
3.1 Technical data on page EN- 7
6.4.1 Version 115V
The mains plug is not pre-attached.
1
Attach and plug in an appropriate mains plug (customer-specific).
6.5 Version 230 V
Mains cable and mains plug are pre-mounted.
1
Plug in the mains plug.
6.6 Automatic starting
The automatic starting function enables the extraction system to be switched on automatically when the welding process
starts. When the welding process starts, the extraction system receives a signal from the current clamp and automatically
starts the extraction process.
WARNING
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
NOTICE
• Before establishing an electrical connection between the product and the mains, check whether the operating voltage
indicated on the nameplate corresponds to the mains voltage.
NOTICE
• The automatic function increases the extraction system’s service life.