4.4.2 Power source
4.4.3 Integrated wire feeder
4.4.4 Extraction system
4.4.5 Generator
► Use a generator with at least 10 kVA for this device.
Tab. 4
General specifications for power source components
Mains voltage, 50–60 Hz
400 V, 3 phases (380–400 V)
Current consumption
Imax. = 12 A, Ieff. = 7 A
Fuse
32 A slow-blow
Max. power consumption
7.5 kVA
Adjustable range
40–250 A
Operating voltage
16–26.5 V
Idle voltage
71 V
Duty cycle 35%
250 A / 26.5 V
Duty cycle 60%
190 A / 23.5 V
Duty cycle 100%
160 A / 22.0 V
Protection type
IP 23
Insulation class
H (180°C)
Type of cooling
Air
Noise emission
< 80 dB(A)
Tab. 5
General specifications for integrated wire feeder components
Wire feeder
Compact
Wire feeder motor
24 V
Feeding speed
2–24 m/min
Wire diameter
0.8–1.0 mm
Tab. 6
General specifications for extraction system components
Connection voltage
230 V
Drive power
1800 W / 1.8 kW
Rated frequency
50 Hz
Filter surface
5 m²
Filter type
Box filter
Filter cleaning method
Disposable filter
Separation efficiency
> 99%
Air inlet
Ø = 60 mm
Max. air volume flow
105 m³/h
Max. vacuum
32 kPa
Sound pressure level LpA
< 80 dB(A)
CAUTION
Device damage
The generator and power source can become damaged if an inefficient generator is used.
► Use only a generator that can ensure 30% more power than the max. power of the device to be
operated. Example: 7.5 kVA (device) + 30% = 9.75 kVA.