EN
-
14
7 Operation
xFUME
®
ADVANCED
6.4 Establishing the power supply
► Note the safety instructions.
2.6 Safety instructions for the power supply on page EN
For the mains voltage and the fuse protection, please refer to:
14 Circuit diagram 115 V on page EN
15 Circuit diagram 230 V on page EN
115 V version
The mains plug is not pre-attached.
► Attach power plug accordingly (as needed) and plug in.
230 V version
The power supply cable and mains plug are mounted.
► Plug in the power plug.
7 Operation
Fig. 3 Control elements/ports on page EN
► Switch the device to On at the On/Off
WARNING
W
Electric shock due to defective cables
Damaged or improperly installed cables can lead to fatal electric shock.
► Check all live cables and connections for proper installation and damage.
► Damaged, deformed or worn parts should only be replaced by a qualified electrician.
WARNING
W
Risk of injury due to fire
Improper use or connection can result in fire. This may result in serious burns.
► Ensure that the operating voltage specified on the nameplate is suitable for the mains voltage.
WARNING
W
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first
use. It can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Use the device only in rooms with sufficient ventilation.
► Ensure that all seals on the device are free from dirt and debris.
► The provided filtration system must be used when operating the device.
► The dust collecting drawer must be closed when operating the device.
► Do not open the dust collecting drawer until at least one minute has passed since the device was
switched off.
► Keep the device closed during operation and during the cleaning process.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner
or a damp cloth.
WARNING
W
Risk of injury due to fire
Improper use or connection can result in fire. This may result in serious burns.
► Ensure that the operating voltage specified on the nameplate is suitable for the connection voltage.
► Do not use the device to extract welding fumes that result from welding oil-wetted parts.
► Do not use the device to extract flammable substances and liquids.
► Do not use the device in areas subject to dust or gas explosion hazards.
From June 2021