7 Operation
xFUME™ ADVANCED HP 230V – CSA
7.2 Manual operation
The device is operated in manual mode (deactivated automatic starting function) as follows:
Fig. 3 Control elements/ports on page EN
Running the cleaning process
The filter membranes must be cleaned regularly to maintain continuous extraction. The cleaning interval
depends on the welding process. We recommend that the filter members are cleaned at least every 2 hours,
however no later than when the service LED illuminates. The service life of the filter membranes can be
lengthened if they are cleaned before the service LED illuminates.
1
Set the <Auto/Manual> switch to <Manual> to
deactivate the automatic starting function.
2
Set the <On/Off> switch to <On>.
The filter membranes are cleaned once.
Continuous extraction is started.
1
To clean the filter membranes, set the <On/Off>
switch to <Off> for a short period of time.
The filter membranes are cleaned once.
2
Set the <On/Off> switch to <On>.
Continuous extraction is started.