EN - 11
PP
4 Putting into operation
4.4 Setting the shielding gas quantity
4.5 Feeding in the wire
1
Insert the wire in the wire feeder as specified by the manufacturer.
2
Remove clamping cap
from handle
3
Swing out seat clamp
laterally.
4
Press the "Current-less wire feed" trigger at the wire feed unit until the wire
emerges from the contact tip.
5
Lock seat clamp
NOTE
• The type and quantity of the shielding gas depends on the welding task
and the gas nozzle geometry.
• Make all shielding gas connections gas-tight.
• To prevent the shielding gas supply from becoming clogged by
impurities, the cylinder valve must be opened briefly before connecting
the cylinder. This will expel any impurities that may be present.
1
Torch neck
2
Clamping cap
3
Flat-head screw
4
Fixing plate
5
Potentiometer (optional)
6
Handle
7
Seat clamp
Fig. 6
Feeding in the wire
1
2
7
5
6
4
3
NOTE
• Each time the wire is changed, make sure that the beginning of the wire is
free of burrs.
• Make sure that the wire feed roll complies with the diameter of the
inserted wire electrode.