MFS service software
9 Setting up the software
EN - 31
9.15 Device type settings
9.15.1 eBOX (MFS-V3 only)
NOTICE
• An active connection to the eBOX is required for these settings.
9.6 Testing the connection on page EN-18
Description
Screenshot
The ‘Max. hot wire current’ field is used to set the
maximum hot wire current for the power source used
with a current of 10 VDC at the power source’s
analog input.
If a connected wire end sensor is used, a check box
can be selected to visually represent the wire end
sensor in the Job Window.
If the wire buffer function is enabled, after stopping
the process the wire is pressed through the rear drive
into the cable assembly to ensure that there is always
sufficient wire buffer in the wire guide when starting
a process.
The wire is pressed into the cable assembly at a
constant speed until the power set for the rear motor
is reached.
When the ‘Monitoring welding voltage’ checkbox is enabled, the system switches off if the specified value is exceeded
.
The wire feed-in rate can be set to between 0.1 and 10 m/min.
The acceleration time of the wire feed-in rate can be set to between 0.5 and 5 seconds.
• Click ‘Apply’ to save all the settings.