EN - 20
9 Setting up the software
MFS service software
9.8 Channel visualisation monitoring settings, user level 2
NOTICE
• Setup files for monitoring purposes should only be created by qualified or trained specialists.
• Save all entries/changes made. Otherwise, these will be lost.
Description
Screenshot
In user level 2 mode, pre-configured setup files
can be read by selecting ‘Load Setup File’.
It is possible to modify existing configurations
or create new setup files.
Eight user-defined channels are available. The
motor current, amount of wire, actual wire
speed, analog and digital inputs, frequency
inputs and all register values can be selected.
The configured settings are only applied once
they have been saved using the parameter
‘Save Setup File’.
It is also necessary to adjust the value in the ‘Recording Time’ field to the length of the welding or brazing process. For example, if a
wire feed duration of 26 seconds is required for a task, it is useful to set the value to 30 seconds so that the graphs are not displayed
for an unnecessarily lengthy amount of time.
The ‘Min. Cycle Time’ field stipulates the number of seconds after which a record should be saved as a log file. This is useful, for
example, if the wire cutters are briefly started between the main cycles but this should not be logged.
The ‘Y-Axis Division’ field specifies the number of vertical graphical divisions.
Содержание MFS-V3 M-Drive
Страница 61: ...MFS Service Software Notizen DE 61 Notizen ...
Страница 62: ...DE 62 Notizen MFS Service Software Notizen ...
Страница 63: ...MFS Service Software Notizen DE 63 Notizen ...
Страница 102: ...EN 40 10 Job mode MFS V3 only MFS service software Memory location 1 is then labelled as used Description Screenshot ...
Страница 123: ...MFS service software Notes EN 61 Notes ...