MFS service software
10 Job mode (MFS-V3 only)
EN - 35
Description
Screenshot
Tolerance of two wire windows in percent
Two tolerance values can be specified for the
deviation of the wire actual value from the
target value. If the upper or lower tolerance
limits are exceeded, a warning is emitted. To
suppress a warning message during the
acceleration phase, an Ignore time [ms] should
be specified that is greater than the system’s
acceleration time constant.
Backwards positioning
Automatic wire retraction can be configured.
This positioning occurs as soon as the wire feed
start signal drops on the end of the seam. The
wire speed can be set to between 0 and 10 m/
min and the positioning route to between 0
and 20 mm.
Forwards and backwards positioning plus delay between backwards and forwards positioning
An automatic wire feed can be configured to
follow the wire retraction process.
This positioning occurs as soon as the wire
retraction positioning is complete and the
specified delay [ms] has passed. The wire
speed can be set to between 0 and 10 m/min
and the positioning route to between 0 and
20 mm.
Содержание MFS-V3 M-Drive
Страница 61: ...MFS Service Software Notizen DE 61 Notizen ...
Страница 62: ...DE 62 Notizen MFS Service Software Notizen ...
Страница 63: ...MFS Service Software Notizen DE 63 Notizen ...
Страница 102: ...EN 40 10 Job mode MFS V3 only MFS service software Memory location 1 is then labelled as used Description Screenshot ...
Страница 123: ...MFS service software Notes EN 61 Notes ...