MFS service software
10 Job mode (MFS-V3 only)
EN - 33
10 Job mode (MFS-V3 only)
The MFS-V3 system can be used in 2 operating modes (field bus systems only).
• Normal control
• Job selection
10.1 Normal control
In normal control mode, all values and signals are specified via the bus interface. The wire is fed forwards
or backwards in speed mode. The wire feed speed is determined by a target setting (bus data word). It is
not possible to use a positioning mode in this mode. In the case of hot wire applications, the hot wire current
is also specified via a target setting (bus data word).
10.2 Job selection
The job selection mode makes it possible to save preconfigured jobs in the eBOX MFS-V3 for appropriate
welding and brazing tasks. During the process, these jobs are then loaded
via a bit pattern (bus interface).
The jobs must be created with the service software, v6.0 or above. A maximum of 64 jobs is possible.
The following parameters can be specified and saved in the job:
• Max. hot wire current [A] (power source)
• Target value for the hot wire current variable via bus or fixed in job
• Target value for the wire speed variable via bus or fixed in job
• Tolerance of two wire windows in percent
• Backwards positioning
• Forwards positioning
• Delay between backwards and forwards positioning
• Motor current limits for pre-warning and errors in relation to both drives
• Job number
• Job description
Содержание MFS-V3 M-Drive
Страница 61: ...MFS Service Software Notizen DE 61 Notizen ...
Страница 62: ...DE 62 Notizen MFS Service Software Notizen ...
Страница 63: ...MFS Service Software Notizen DE 63 Notizen ...
Страница 102: ...EN 40 10 Job mode MFS V3 only MFS service software Memory location 1 is then labelled as used Description Screenshot ...
Страница 123: ...MFS service software Notes EN 61 Notes ...