7 Operation
iROB
®
501, iROB
®
401, iROB
®
301
7.5 Setting internal functions
Internal functions provide additional adjustment options for the welding and/or device parameters and can
be adjusted by the user according to requirements.
The internal functions are activated by setting or changing a value.
7.5.1 Making settings
7.5.2 Description of the internal functions
Some internal functions can be saved with the welding parameters. These are marked with “Yes” in the
Storage option row of the tables in the descriptions.
1
Press and hold the <Function> button for 1 or more seconds.
In the left digital display, the function number blinks. The parameter stored for
the function number is displayed in the right digital display.
2
Use the <Parameter setting> knob to select the function number to
be edited.
3
Press the <Function> button.
The right digital display blinks.
4
Use the <Parameter setting> knob to set the desired value.
5
Press the <Function> button to return the display to its initial state. The left
digital display blinks.
6
Press and hold the <Function> button for 1 or more seconds.
The internal function has been set and the display returns to the initial state.
F
F
F
F
Tab. 13
Overview of internal functions
No./function name
Adjustable
range
Starting value
F1: No function
–
–
ON/OFF
OFF
F3: Switching the heat input display
ON/OFF
OFF
0 to 10 s
0 s
0 to10 s
0 s
F8: Setting the display hold time
0 to 60 s
20 s
F12: Setting the run-on time for the cooling water
pump (option)
20 to 60 min
20 min
F14/F15: Adjusting the start control
(time and current)
−100 to +100%
0%
−1 to 1 m/min
0 m/min
F17/F18: Setting the backburn time/backburn
voltage
−50 to 50 ms
−9.9 to +9.9 V
0 ms
0 V
F19: Setting the switching off of the alarm
ON/OFF
OFF
F20: Setting the lower threshold value of the
mains voltage monitoring
260 to 400 V
320 V
F21: Activating the maximum capacity of
the cooling fan
ON/OFF
OFF
F22: Deactivating the button tones
ON/OFF
ON
F23: Setting the time period until stand-by mode
0 to 10 min
0 min
F24: Setting the wire feed speed
ON/OFF
OFF
F25–F28: Setting external outputs
0/4
0
F29–F32: Setting external inputs
0 to 12
0