EN - 19
CAT 3
11 Disassembly
11 Disassembly
NOTICE
• Please also consult the operating instructions for the welding
components, such as the power source and compressed air line.
Fault
Cause
Troubleshooting
Torch mount cannot
be attached
• Wrong torch mount used
• Use the correct torch mount
•
CAT 3
mounting flange is defective
• Send the
CAT 3
for repair
CAT 3
does not
activate the stop
signal
• Cable not connected between the
CAT 3
and the cable assembly
• Connect the cable
• Cable defective
• Replace the cable
•
CAT 3
switch defective
• Send the
CAT 3
for repair
The
CAT 3
does not
reset to the zero
position
• Mounted load is too heavy
• Reduce the mounted load
• Observe the data provided by the
manufacturer
• Mechanical defect
• Send the
CAT 3
for repair
• Attachment parts (bracket etc.) not
correctly connected
• Check if the attachment parts are
properly connected
CAT 3
triggers
despite there not
being a fault
• Mounted load is too heavy
• Adapt the load to the
specifications
3.1 Technical data on page EN-7
• Robot speed is too high
Tab. 13
Troubleshooting
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance,
servicing, assembly, disassembly and repair work:
• Switch off the power source.
• Close the compressed air supply.
• Close the gas supply.
• Switch off the entire welding system.
• Pull the mains plug at the robot welding power source.
Содержание CAT3
Страница 4: ...DE 4 1 Identifikation CAT 3 1 1 EU Konformitätserklärung ...
Страница 24: ...EN 4 1 Identification CAT 3 1 1 EU Declaration of Conformity ...
Страница 41: ...EN 21 CAT 3 Notes Notes ...
Страница 44: ...FR 4 1 Identification CAT 3 1 1 Déclaration de conformité UE ...
Страница 63: ...FR 23 CAT 3 Notes Notes ...
Страница 66: ...ES 4 1 Identificación CAT 3 1 1 Declaración de conformidad de la UE ...
Страница 85: ...ES 23 CAT 3 Notas Notas ...
Страница 86: ...ES 24 Notas CAT 3 Notas ...
Страница 87: ...ES 25 CAT 3 Notas Notas ...