EN - 16
BAL.0193.0 • 2018-07-31
7 Operation
MT/AUT/AUT RAB
6.6 Feeding in the wire
Fig. 5 Mounting the hose assembly on the machine side on page EN-14
1
Lay the cable assembly
straight out.
2
Insert the wire in the wire feed unit
as specified by the manufacturer.
3
Press the "Wire Jog" push-button at the wire feed unit
until the wire comes out of the
contact tip.
7 Operation
1
Open the shielding gas cylinder.
2
Switch on the power supply.
3
Set the welding parameters.
4
Start welding.
8 Decommissioning
1
Stop welding.
2
Wait until the shielding gas flow has subsided and switch off power supply.
3
Close the valve of the shielding gas cylinder.
CAUTION
Risk of injury
Puncture or cut-in wounds may be caused by the wire electrode.
• Keep your hands out of the danger zone.
• Wear the correct protective gloves.
NOTICE
• Each time the wire is replaced, make sure that the start of the wire is free of burrs and not
bent.
NOTICE
• When putting the system out of operation, ensure that the procedures for switching off
each of the welding system components are observed.
• As liquid-cooled cable assemblies start to leak when they overheat, the coolant
recirculator should continue running for approx. 5 min. after welding.