EN - 13
ABIROB
®
A
8 Putting out of operation
7.1 Welding process
1
Open the shielding gas cylinder.
2
Switch on the power supply.
8 Putting out of operation
1
Wait until the shielding gas flow has subsided.
2
Close the shut-off-valve for the gas supply.
3
Switch off the power supply.
9 Maintenance and cleaning
Regular and lasting maintenance and cleaning are the prerequisite of a long
life and a perfect function. In doing so, observe the following:
WARNING
Dazzling of the eyes
The arc produced by welding may damage the eyes.
• Wear protective clothing or eye protection.
NOTE
• The welding torch may only be operated by qualified personnel.
• Ensure that all required parameters, for example welding current, wire
feed, etc., have been set at the welding power supply according to your
welding task.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply.
• Cut off the compressed air supply.
• Pull the mains plug.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation.
• Replace any damaged, deformed or worn parts.