8 Putting out of operation
ABICAR ADVANCED
8 Putting out of operation
► When putting the system out of operation, ensure that the procedures for switching off the welding
components are observed.
1
Switch on/off the device.
2
Wait until the shielding gas post-flow time has passed.
3
Close the shut-off valve for the gas supply.
4
Switch off the power source.
5
Pull out the mains plug.
9 Maintenance and cleaning
Regular ongoing maintenance and cleaning are prerequisites for a long service life and trouble-free
operation.
The maintenance cycle is determined by the work environment and by the length of the scheduled intervals
between maintenance of the devices. The maintenance cycle is usually three months. If the device is
operated for more than 8 hours a day, the maintenance intervals should be changed as needed.
WARNING
Electric shock caused by incorrectly installed and damaged cables
Use of damaged or improperly installed cables may result in a potentially fatal electric shock.
► Check all live cables and connections for proper installation and damage.
► Have any damaged, deformed or worn parts replaced only by a qualified electrician.
CAUTION
Risk of injury due to unexpected start
If the device is energised during maintenance, cleaning or disassembly work, rotating parts may
unexpectedly start up and cause crushing.
► Switch off the device.
► Disconnect all electrical connections.