EN
-
14
6 Putting into operation
ABICAR ADVANCED
6.3 Positioning guide arms
In order to ensure restricted guidance along the contact surface, the guide arm
it is shorter than the guide arm
. The adjustment depends on the direction of movement and the length of
the guide arm. The difference should be approx. 10 mm for a straight component.
1
and advance by 10 mm or one groove.
2
Retighten the knurled screw
6.4 Connecting the weld start signal cable
The device can be operated with two welding torches.
Fig. 7
Adjustment of restricted guidance
A
Component
B
Guide arm, rear
C
Knurled screws
D
Angle of approach
E
Guide arm, front
Contact surface of the component
Travel direction
A
B
C
D
C
G
WARNING
Electric shock caused by incorrectly installed and damaged cables
Use of damaged or improperly installed cables may result in a potentially fatal electric shock.
► Check all live cables and connections for proper installation and damage.
► Have any damaged, deformed or worn parts replaced only by a qualified electrician.
WARNING
Risk of injury due to fire
A fire may occur due to improper use or connection. They could cause major burns.
► Ensure that the operating voltage specified on the nameplate corresponds to the connection voltage.