Abexo SH230 Скачать руководство пользователя страница 1

Instructions for assembly and use

MADE

 IN 

ITALY

SH230

cod

.

APE-528/0230

www.abexo.tech

AB-00057.IT - rev.2/2024

TECHNICAL FEATURES

Before installing the product, be sure to disconnect the power supply. See the table 

opposite for product characteristics:

PROGRAMMING OPERATION TIME

With the damper closed, set microswitch DIP2 to ON, DIP1 to OFF and DIP5/DIP6 to 

ON. Enter programming by pressing the external button (connected between DIP9 

and 10) or a previously inserted transmitter. A beep and blink will indicate the start 

of programming, and the door will open until it reaches its end stop. Once reached 

transmit the close command by pressing the external button or a transmitter. The 

door will reach its closing limit and two beeps accompanied by a flashing will indica-

te the end of programming. Reposition the dips to the previous position.

PROGRAMMING AUTOMATIC CLOSING TIME

Programming can be done only with the door at rest and with DIP1 and DIP2 

microswitches set to ON. Press the external button or inserted transmitter button; a 

beep and a flash will indicate the start of programming. Finish by pressing the 

button in question again after the desired time; Two beeps accompanied by a 

flashing will confirm successful programming. Reposition the dips to the previous 

position.

SETTING OPTIONS

DIP1: Timer/Auto closing selector:

· ON - automatic closing with timer.

· OFF - automatic closing disabled.

DIP2: Programming timer:

· ON - programming operation time (DIP1 OFF).

            Programming closing time (DIP1 ON).

· OFF - programming time disabled.

DIP5

ON
ON

OFF
OFF

DIP6

ON

OFF

ON

OFF

Photocell and border disabled (BY DEFAULT))
Flush photocell and border enabled
Photocell and resistive border enabled.
Photocell enabled border disabled.

Power supply
Motor power
Fuse
Run time
Closing time
Code combinations
Number of codes
Programming of codes
Function selection
Frequency
Approval
Sensitivity
Application range
Antenna
Operating temperature

 230V ac +-10%
1HP (1350 W)
6,3 A
Default 25 sec, programmable up to 2.5 minutes
Default 20 sec, programmable up to 3 minutes
72 million codes
50
Self-learning
Stores code function
433.92 Mhz
2014/35/UE ,2014/30/UE,2014/53/EU
Greater than -100 dBm
Standard 50m / man present 10m
Built-in
Da -10ºC a 70ºC

brand
CAME
ENTREMATIC
ABEXO
DITEC
TELCOMA
PUJOL
LUTEC
SUPERLIFT
NICE
BFT
JCM

model
TOP 433EE
ZEN
EGO 433
BIXLS2
TANGO 4SW
VARIO
HT12E
N3588
FLO
MITTO433
NEO10

brand
GIBIDI 
APRIMATIC
ACM

model
AU03000 - AU03010 - AU01600
TM4
TX2 COLOR

SH230CONTROL UNIT 

FOR SHUTTERS

AB Tecno Srl

Via Cicogna 95 - 40068 San Lazzaro di Savena (BO)

Tel: +39 051 6259580 - fax: +39 051 6259600

[email protected]www.abexo.tech

ABEXO is a registered trademark

property of AB Tecno Srl

The technical characteristics can be subject to variations without advance notice. AB Tecno S.r.l. doesn’t take responsibilities for damages caused by the improper use of the device.

1 2 3 4 5 6

STANDARD RADIO CONTROL 

COMPATIBILITY TABLE

 HCS RADIO CONTROL 

COMPATIBILITY TABLE

DIP3: Radio programming:

· ON - radio programming new transmitters enabled

· OFF - radio programming disabled

:

DIP4: Man Present (with jumper J2 closed hold down the transmitter Close button):

· ON - to realize the close, the transmitter button or external button must be held down. If   

            not held down, the operation stops.

· OFF - normal operation.

DIP5-6: Disable/Enable photocell and wire or resistive border:

By default, with jumper J2 open, the control unit is stepping, so pressing the single button 
during opening or closing stops the door. Pressing it again will resume the reverse direction 
from the previous direction. With jumper J2 closed, the transmitter will instead operate with 
three buttons. (Open-Stop-Close). Recommended option for DEADMAN.