2. Installation
GPI, Ethernet & Power Connection
20. Within a few seconds, the AirCleaner web page will change to indicate the
AirCleaner Ethernet module is being rebooted, as shown below. The new IP
Address will be listed, as indicated by the arrow in the illustration. The reboot
will take approximately 45 seconds to complete.
21. As of the writing of this manual, there is no internal communication between
the Ethernet module and the front panel LCD display inside AirCleaner.
Therefore, the only status indicator for the IP Address save & reboot operation
are the two l.e.d.s above the Ethernet connector on the AirCleaner rear panel.
These l.e.d.s provide the reboot status as shown in the table below.
22. After waiting 45 seconds and seeing the Ethernet amber l.e.d. is ON solid, with
the green l.e.d. blinking, disconnect the cross-over Ethernet cable between the
AirCleaner and your Windows PC.
23. Reset the IP Address and Subnet Mask (if required) in your Windows PC,
according to the values you had noted in step (8.) on page 17 above.
24. Connect AirCleaner to your local Ethernet LAN using a standard Ethernet
cable (NOT a cross-over cable!).
Table 2-1. Ethernet Port LED indicators for AirCleaner reboot status
Function
Left (Amber) L.E.D.
Right (Green) L.E.D.
Begin Reboot
ON
Blinking
~10 Seconds
ON
ON or OFF
~15 Seconds
ON
ON
~35 Seconds
OFF
ON
~37 Seconds
ON
ON
~45 Seconds
ON
Blinking
Содержание AirCleaner
Страница 2: ...ii AirCleaner User Guide ...
Страница 10: ...x AirCleaner User Guide Table of Contents ...
Страница 54: ...44 AirCleaner User Guide 3 Updating Software Firmware Updating Software Firmware ...
Страница 100: ...90 AirCleaner User Guide 4 Operations Control Panel Menu Item Descriptions ...
Страница 106: ...96 AirCleaner User Guide Index ...